{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-5608 exists.","fix":"No fix has been published for CVE-2025-5608 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-5608 is a high-severity memory corruption vulnerability in Tenda Ac18 Firmware, published on 4 Jun 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-5608 and fix it if it is affected.\n\nWhat it is: CVE-2025-5608 is a high-severity memory corruption vulnerability in Tenda Ac18 Firmware, published on 4 Jun 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-5608 exists.\n\nAffected product: Tenda Ac18 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-5608/ (Markdown: https://insights.sbomify.com/CVE-2025-5608/index.md)","id":"CVE-2025-5608","markdown":"https://insights.sbomify.com/CVE-2025-5608/index.md","name":"CVE-2025-5608","record":{"aliases":["GHSA-43mc-8f4r-rrm4"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC18 router","requires_auth":"low_privilege","summary":"A remote attacker can trigger a buffer overflow in the Tenda AC18 router's reboot timer configuration, potentially leading to code execution or service disruption.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac18_firmware","vendor":"tenda"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formsetreboottimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda AC18 SetSysAutoRebbotCfg formsetreboottimer buffer overflow","id":"CVE-2025-5608","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac18_firmware","products":["tenda:ac18_firmware"],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"Tenda AC18 AdvSetLanip fromadvsetlanip buffer overflow","id":"CVE-2025-5609"},"packages":[],"prev":{"headline":"Tenda AC18 setPptpUserList formSetPPTPUserList buffer overflow","id":"CVE-2025-5607"},"products":["AC18"],"published":"2025-06-04","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57575","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57579","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57580","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57581","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57582","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2024-57583","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-33835","kev_date_added":null,"published":"2024-05-01"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-06-04","vendors":["Tenda"]},"summary":"A remote attacker can trigger a buffer overflow in the Tenda AC18 router's reboot timer configuration, potentially leading to code execution or service disruption.","url":"https://insights.sbomify.com/CVE-2025-5608/"}