{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-5629 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-5629 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-5629 is a high-severity memory corruption vulnerability in Tenda Ac10 Firmware, published on 5 Jun 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-5629 and fix it if it is affected.\n\nWhat it is: CVE-2025-5629 is a high-severity memory corruption vulnerability in Tenda Ac10 Firmware, published on 5 Jun 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-5629 in the wild and no public exploit code.\n\nAffected product: Tenda Ac10 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-5629/ (Markdown: https://insights.sbomify.com/CVE-2025-5629/index.md)","id":"CVE-2025-5629","markdown":"https://insights.sbomify.com/CVE-2025-5629/index.md","name":"CVE-2025-5629","record":{"aliases":["GHSA-pxpm-gqm6-6pwh"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC10 router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a buffer overflow in the Tenda AC10 router's PPTP server configuration handler, potentially leading to arbitrary code execution.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac10_firmware","vendor":"tenda"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A vulnerability, which was classified as critical, was found in Tenda AC10 up to 15.03.06.47. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg of the component HTTP Handler. The manipulation of the argument startIp/endIp leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Tenda AC10 HTTP SetPptpServerCfg formSetPPTPServer buffer overflow","id":"CVE-2025-5629","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac10_firmware","products":["tenda:ac10_firmware"],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"D-Link DIR-816 form2lansetup.cgi stack-based overflow","id":"CVE-2025-5630"},"packages":[],"prev":{"headline":"SourceCodester Food Menu Manager Add Menu index.php cross site scripting","id":"CVE-2025-5628"},"products":["AC10"],"published":"2025-06-05","related":[{"cvss_score":9.8,"headline":"Tenda AC7, AC9, and AC10 Routers Command Injection","id":"CVE-2018-14558","kev_date_added":"2021-11-03","published":"2018-10-30"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-67073","kev_date_added":null,"published":"2025-12-17"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-45779","kev_date_added":null,"published":"2025-05-12"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-25456","kev_date_added":null,"published":"2025-04-15"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-25674","kev_date_added":null,"published":"2025-02-20"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2025-25675","kev_date_added":null,"published":"2025-02-20"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-45479","kev_date_added":null,"published":"2023-11-29"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-06-05","vendors":["Tenda"]},"summary":"Remote attackers can trigger a buffer overflow in the Tenda AC10 router's PPTP server configuration handler, potentially leading to arbitrary code execution.","url":"https://insights.sbomify.com/CVE-2025-5629/"}