{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-57085 exists.","fix":"No fix has been published for CVE-2025-57085 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-57085 is a critical memory corruption vulnerability in Tenda W30e Firmware, published on 9 Sep 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-57085 and fix it if it is affected.\n\nWhat it is: CVE-2025-57085 is a critical memory corruption vulnerability in Tenda W30e Firmware, published on 9 Sep 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-57085 exists.\n\nAffected product: Tenda W30e Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-57085/ (Markdown: https://insights.sbomify.com/CVE-2025-57085/index.md)","id":"CVE-2025-57085","markdown":"https://insights.sbomify.com/CVE-2025-57085/index.md","name":"CVE-2025-57085","record":{"aliases":["GHSA-7f5g-622m-45vg"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda W30E router","requires_auth":"none","summary":"Attackers can cause a Denial of Service on Tenda W30E routers via a crafted request exploiting a stack overflow in the UploadCfg function.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"w30e_firmware","vendor":"tenda"}],"cvss":{"score":9.8,"severity":"critical","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the v17 parameter in the UploadCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Memory corruption in n/a","id":"CVE-2025-57085","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:w30e_firmware","products":["tenda:w30e_firmware"],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Memory corruption in n/a","id":"CVE-2025-57086"},"packages":[],"prev":{"headline":"Memory corruption in n/a","id":"CVE-2025-57078"},"products":["n/a"],"published":"2025-09-09","related":[{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2026-38835","kev_date_added":null,"published":"2026-04-21"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-32286","kev_date_added":null,"published":"2024-04-17"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-49402","kev_date_added":null,"published":"2023-12-07"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2023-49403","kev_date_added":null,"published":"2023-12-07"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-49404","kev_date_added":null,"published":"2023-12-07"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-49405","kev_date_added":null,"published":"2023-12-07"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-09-11","vendors":["n/a"]},"summary":"Attackers can cause a Denial of Service on Tenda W30E routers via a crafted request exploiting a stack overflow in the UploadCfg function.","url":"https://insights.sbomify.com/CVE-2025-57085/"}