{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-5742 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-5742 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-5742 is a medium-severity cross-site scripting vulnerability in Schneider Electric EVLink WallBox, published on 10 Jun 2025. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-5742 and fix it if it is affected.\n\nWhat it is: CVE-2025-5742 is a medium-severity cross-site scripting vulnerability in Schneider Electric EVLink WallBox, published on 10 Jun 2025. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-5742 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EVLink WallBox. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-5742/ (Markdown: https://insights.sbomify.com/CVE-2025-5742/index.md)","id":"CVE-2025-5742","markdown":"https://insights.sbomify.com/CVE-2025-5742/index.md","name":"CVE-2025-5742","record":{"aliases":["GHSA-6mv2-8pp6-4rv3"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["code_execution","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"EV charging station","requires_auth":"low_privilege","summary":"An authenticated user can inject malicious scripts via configuration parameters, potentially compromising the EVLink WallBox web interface.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":5.1,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:L/VI:N/VA:N/SC:L/SI:L/SA:N","version":"4.0"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"CWE-79: Improper Neutralization of Input During Web Page Generation (‘Cross-site Scripting’)\nvulnerability exists when an authenticated user modifies configuration parameters on the web server","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in EVLink WallBox","id":"CVE-2025-5742","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Command injection in EVLink WallBox","id":"CVE-2025-5743"},"packages":[],"prev":{"headline":"Path traversal in EVLink WallBox","id":"CVE-2025-5741"},"products":["EVLink WallBox"],"published":"2025-06-10","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-06-10","vendors":["Schneider Electric"]},"summary":"An authenticated user can inject malicious scripts via configuration parameters, potentially compromising the EVLink WallBox web interface.","url":"https://insights.sbomify.com/CVE-2025-5742/"}