{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-58083 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-58083 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-58083 is a critical missing authorization vulnerability in General Industrial Controls Lynx+ Gateway, published on 14 Nov 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-58083 and fix it if it is affected.\n\nWhat it is: CVE-2025-58083 is a critical missing authorization vulnerability in General Industrial Controls Lynx+ Gateway, published on 14 Nov 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-58083 in the wild and no public exploit code.\n\nAffected product: General Industrial Controls Lynx+ Gateway. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-58083/ (Markdown: https://insights.sbomify.com/CVE-2025-58083/index.md)","id":"CVE-2025-58083","markdown":"https://insights.sbomify.com/CVE-2025-58083/index.md","name":"CVE-2025-58083","record":{"aliases":["GHSA-gg5h-m9wx-57xr"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["denial_of_service","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial Gateway","requires_auth":"none","summary":"An attacker can remotely reset the General Industrial Controls Lynx+ Gateway due to missing authentication in its embedded web server.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":9.2,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:H/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"General Industrial Controls Lynx+ Gateway \n is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function","id":"CVE-2025-58083","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"Mattermost Desktop App crashes when clicking on malformed external URL","id":"CVE-2025-58084"},"packages":[],"prev":{"headline":"Hardcoded credentials in SS1","id":"CVE-2025-58081"},"products":["Lynx+ Gateway"],"published":"2025-11-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-11-17","vendors":["General Industrial Controls"]},"summary":"An attacker can remotely reset the General Industrial Controls Lynx+ Gateway due to missing authentication in its embedded web server.","url":"https://insights.sbomify.com/CVE-2025-58083/"}