{"answers":{"affected":"It affects 9 products.","exploited":"There is no known exploitation of CVE-2025-5824 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-5824 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-5824 is a medium-severity authentication bypass vulnerability in Autel MaxiCharger AC Wallbox Commercial, published on 25 Jun 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-5824 and fix it if it is affected.\n\nWhat it is: CVE-2025-5824 is a medium-severity authentication bypass vulnerability in Autel MaxiCharger AC Wallbox Commercial, published on 25 Jun 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-5824 in the wild and no public exploit code.\n\nAffected product: Autel MaxiCharger AC Wallbox Commercial. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-5824/ (Markdown: https://insights.sbomify.com/CVE-2025-5824/index.md)","id":"CVE-2025-5824","markdown":"https://insights.sbomify.com/CVE-2025-5824/index.md","name":"CVE-2025-5824","record":{"aliases":["GHSA-vjqh-vxpx-8294"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"EV charging station","requires_auth":"none","summary":"Network-adjacent attackers can bypass authentication on Autel MaxiCharger AC Wallbox Commercial by pairing a malicious Bluetooth device due to insufficient origin validation.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"zdi","cpe":[{"product":"maxicharger_ac_elite_business_c50_firmware","vendor":"autel"},{"product":"maxicharger_ac_pro_firmware","vendor":"autel"},{"product":"maxicharger_ac_ultra_firmware","vendor":"autel"},{"product":"maxicharger_dc_compact_mobile_firmware","vendor":"autel"},{"product":"maxicharger_dc_compact_pedestal_firmware","vendor":"autel"},{"product":"maxicharger_dc_fast_firmware","vendor":"autel"},{"product":"maxicharger_dc_hipower_firmware","vendor":"autel"},{"product":"maxicharger_dh480_firmware","vendor":"autel"},{"product":"maxicharger_single_charger_firmware","vendor":"autel"}],"cvss":{"score":5,"severity":"medium","source":"cna","vector":"CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L","version":"3.0"},"cwes":[{"id":"CWE-346","name":"Origin Validation Error"}],"description":"Autel MaxiCharger AC Wallbox Commercial Origin Validation Error Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Autel MaxiCharger AC Wallbox Commercial. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the handling of bluetooth pairing requests. The issue results from insufficient validation of the origin of commands. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-26353.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Autel MaxiCharger AC Wallbox Commercial Origin Validation Error Authentication Bypass Vulnerability","id":"CVE-2025-5824","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability","id":"CVE-2025-5825"},"packages":[],"prev":{"headline":"Autel MaxiCharger AC Wallbox Commercial Serial Number Exposed Dangerous Method Information Disclosure Vulnerability","id":"CVE-2025-5823"},"products":["Autel MaxiCharger AC Wallbox Commercial"],"published":"2025-06-25","related":[{"cvss_score":8.8,"headline":"Memory corruption in Autel MaxiCharger AC Wallbox Commercial","id":"CVE-2025-5827","kev_date_added":null,"published":"2025-06-25"},{"cvss_score":8.8,"headline":"Memory corruption in Autel MaxiCharger AC Wallbox Commercial","id":"CVE-2025-5830","kev_date_added":null,"published":"2025-06-25"},{"cvss_score":8.8,"headline":"Memory corruption in MaxiCharger AC Elite Business C50","id":"CVE-2024-23957","kev_date_added":null,"published":"2024-09-28"},{"cvss_score":8.8,"headline":"Memory corruption in MaxiCharger AC Elite Business C50","id":"CVE-2024-7795","kev_date_added":null,"published":"2024-08-21"},{"cvss_score":8,"headline":"Memory corruption in MaxiCharger AC Elite Business C50","id":"CVE-2024-23959","kev_date_added":null,"published":"2024-09-28"},{"cvss_score":8,"headline":"Memory corruption in MaxiCharger AC Elite Business C50","id":"CVE-2024-23967","kev_date_added":null,"published":"2024-09-28"},{"cvss_score":7.5,"headline":"Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability","id":"CVE-2025-5825","kev_date_added":null,"published":"2025-06-25"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-06-25","vendors":["Autel"]},"summary":"Network-adjacent attackers can bypass authentication on Autel MaxiCharger AC Wallbox Commercial by pairing a malicious Bluetooth device due to insufficient origin validation.","url":"https://insights.sbomify.com/CVE-2025-5824/"}