CVE-2025-58405 Lack of protection mechanisms against Clickjacking attacks
Attackers can embed the CGM CLININET application in an iframe to trick users into unintended actions, bypassing CSRF protections.
- Exploited in the wild
- Not known
- Login needed
- Not needed
- Attackable
- Over the internet
- Victim action needed
- A user has to click or open something
- Fix
- None listed
What is CVE-2025-58405?
CVE-2025-58405 is a medium-severity vulnerability in CGM CLININET, published on 2 Mar 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.
Official description
The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP security headers nor HTML-based frame‑busting protections were detected. As a result, an attacker can embed the application inside a maliciously crafted IFRAME and trick users into performing unintended actions, including potentially bypassing CSRF/XSRF defenses.
Weakness: CWE-1021
Which versions are affected by CVE-2025-58405?
It affects 1 product.
Products include Cgm Clininet.
How do I fix CVE-2025-58405?
No fix has been published for CVE-2025-58405 yet. Limit exposure of the affected software until one is available.
Is CVE-2025-58405 being exploited?
There is no known exploitation of CVE-2025-58405 in the wild and no public exploit code.
Other vulnerabilities in CGM CLININET
Sources
Also known as GHSA-mw7x-2vvf-4c4h.