{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-58422 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-58422 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-58422 is a low-severity vulnerability in RICOH Streamline NX, published on 8 Sep 2025. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-58422 and fix it if it is affected.\n\nWhat it is: CVE-2025-58422 is a low-severity vulnerability in RICOH Streamline NX, published on 8 Sep 2025. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-58422 in the wild and no public exploit code.\n\nAffected product: RICOH Streamline NX. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-58422/ (Markdown: https://insights.sbomify.com/CVE-2025-58422/index.md)","id":"CVE-2025-58422","markdown":"https://insights.sbomify.com/CVE-2025-58422/index.md","name":"CVE-2025-58422","record":{"aliases":["GHSA-r277-f4fh-cwv4"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Document management software","requires_auth":"none","summary":"An attacker performing a man-in-the-middle attack can tamper with operation history in RICOH Streamline NX by altering HTTP requests.","user_interaction":"required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"jpcert","cpe":[],"cvss":{"score":2.3,"severity":"low","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-348","name":"Use of Less Trusted Source"}],"description":"RICOH Streamline NX versions 3.5.1 to 24R3 are vulnerable to tampering with operation history. If an attacker can perform a man-in-the-middle attack, they may alter the values of HTTP requests, which could result in tampering with the operation history of the product’s management tool.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Other in RICOH Streamline NX","id":"CVE-2025-58422","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"Advantech DeviceOn/iEdge Path Traversal","id":"CVE-2025-58423"},"packages":[],"prev":{"headline":"Not used","id":"CVE-2025-58421"},"products":["RICOH Streamline NX"],"published":"2025-09-08","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-09-08","vendors":["Ricoh Company, Ltd."]},"summary":"An attacker performing a man-in-the-middle attack can tamper with operation history in RICOH Streamline NX by altering HTTP requests.","url":"https://insights.sbomify.com/CVE-2025-58422/"}