{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-5850 exists.","fix":"No fix has been published for CVE-2025-5850 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-5850 is a high-severity memory corruption vulnerability in Tenda Ac15 Firmware, published on 8 Jun 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-5850 and fix it if it is affected.\n\nWhat it is: CVE-2025-5850 is a high-severity memory corruption vulnerability in Tenda Ac15 Firmware, published on 8 Jun 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-5850 exists.\n\nAffected product: Tenda Ac15 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-5850/ (Markdown: https://insights.sbomify.com/CVE-2025-5850/index.md)","id":"CVE-2025-5850","markdown":"https://insights.sbomify.com/CVE-2025-5850/index.md","name":"CVE-2025-5850","record":{"aliases":["GHSA-4287-9xx6-3794"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC15 router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a buffer overflow in the Tenda AC15 router's LED scheduling handler, potentially leading to code execution or service disruption.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac15_firmware","vendor":"tenda"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A vulnerability was found in Tenda AC15 15.03.05.19_multi. It has been declared as critical. This vulnerability affects the function formsetschedled of the file /goform/SetLEDCf of the component HTTP POST Request Handler. The manipulation of the argument Time leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda AC15 HTTP POST Request SetLEDCf formsetschedled buffer overflow","id":"CVE-2025-5850","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac15_firmware","products":["tenda:ac15_firmware"],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"Tenda AC15 HTTP POST Request AdvSetLanip fromadvsetlanip buffer overflow","id":"CVE-2025-5851"},"packages":[],"prev":{"headline":"Tenda AC15 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow","id":"CVE-2025-5849"},"products":["AC15"],"published":"2025-06-08","related":[{"cvss_score":9.8,"headline":"Tenda AC1900 Router AC15 Model Remote Code Execution","id":"CVE-2020-10987","kev_date_added":"2021-11-03","published":"2020-07-13"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-24103","kev_date_added":null,"published":"2026-03-03"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2026-24101","kev_date_added":null,"published":"2026-03-02"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2026-24105","kev_date_added":null,"published":"2026-03-02"},{"cvss_score":9.8,"headline":"Information disclosure in n/a","id":"CVE-2025-63666","kev_date_added":null,"published":"2025-11-12"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29462","kev_date_added":null,"published":"2025-04-03"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2025-25632","kev_date_added":null,"published":"2025-03-05"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-06-09","vendors":["Tenda"]},"summary":"Remote attackers can trigger a buffer overflow in the Tenda AC15 router's LED scheduling handler, potentially leading to code execution or service disruption.","url":"https://insights.sbomify.com/CVE-2025-5850/"}