{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-5852 exists.","fix":"No fix has been published for CVE-2025-5852 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-5852 is a high-severity memory corruption vulnerability in Tenda Ac6 Firmware, published on 9 Jun 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-5852 and fix it if it is affected.\n\nWhat it is: CVE-2025-5852 is a high-severity memory corruption vulnerability in Tenda Ac6 Firmware, published on 9 Jun 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-5852 exists.\n\nAffected product: Tenda Ac6 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-5852/ (Markdown: https://insights.sbomify.com/CVE-2025-5852/index.md)","id":"CVE-2025-5852","markdown":"https://insights.sbomify.com/CVE-2025-5852/index.md","name":"CVE-2025-5852","record":{"aliases":["GHSA-jx3m-4496-3hgp"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC6 router","requires_auth":"low_privilege","summary":"A remote attacker can trigger a buffer overflow in the Tenda AC6 router's PPTP user list handler, potentially leading to arbitrary code execution.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac6_firmware","vendor":"tenda"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A vulnerability classified as critical has been found in Tenda AC6 15.03.05.16. Affected is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda AC6 setPptpUserList formSetPPTPUserList buffer overflow","id":"CVE-2025-5852","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac6_firmware","products":["tenda:ac6_firmware"],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"Tenda AC6 SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow","id":"CVE-2025-5853"},"packages":[],"prev":{"headline":"Tenda AC15 HTTP POST Request AdvSetLanip fromadvsetlanip buffer overflow","id":"CVE-2025-5851"},"products":["AC6"],"published":"2025-06-09","related":[{"cvss_score":9.8,"headline":"Auth bypass in AC6 V5.0","id":"CVE-2025-27129","kev_date_added":null,"published":"2025-08-20"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29029","kev_date_added":null,"published":"2025-03-14"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29030","kev_date_added":null,"published":"2025-03-14"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29031","kev_date_added":null,"published":"2025-03-14"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-25343","kev_date_added":null,"published":"2025-02-12"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-40830","kev_date_added":null,"published":"2023-10-03"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2023-40837","kev_date_added":null,"published":"2023-08-30"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-06-09","vendors":["Tenda"]},"summary":"A remote attacker can trigger a buffer overflow in the Tenda AC6 router's PPTP user list handler, potentially leading to arbitrary code execution.","url":"https://insights.sbomify.com/CVE-2025-5852/"}