{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-5946 exists.","fix":"No fix has been published for CVE-2025-5946 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-5946 is a high-severity command injection vulnerability in Centreon Centreon Web, published on 14 Oct 2025. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-5946 and fix it if it is affected.\n\nWhat it is: CVE-2025-5946 is a high-severity command injection vulnerability in Centreon Centreon Web, published on 14 Oct 2025. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-5946 exists.\n\nAffected product: Centreon Centreon Web. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-5946/ (Markdown: https://insights.sbomify.com/CVE-2025-5946/index.md)","id":"CVE-2025-5946","markdown":"https://insights.sbomify.com/CVE-2025-5946/index.md","name":"CVE-2025-5946","record":{"aliases":["GHSA-mpw2-f23v-c9fv"],"analysis":{"component_type":"web_application","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Centreon Infra Monitoring","requires_auth":"high_privilege","summary":"Privileged users can inject OS commands via poller reload configuration, leading to remote code execution on the monitoring server.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Centreon","cpe":[{"product":"centreon_web","vendor":"centreon"}],"cvss":{"score":7.2,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection.\nOn the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":"2025-09-24","github_poc":0,"max_poc_stars":null,"metasploit":1,"nuclei":0,"refs":[{"date":"2025-09-24","kind":"metasploit","ref":"exploit/linux/http/centreon_auth_rce_cve_2025_5946","stars":null,"title":"Centreon authenticated command injection leading to RCE via broker engine \"reload\" parameter"}],"tier":"weaponised"},"has_fix":false,"headline":"RCE via the poller reload feature available only to user with high privilege","id":"CVE-2025-5946","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"centreon:centreon_web","products":["centreon:centreon_web"],"type":"command_injection","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"Service Finder Bookings \u003c= 6.0 - Authentication Bypass via User Switch Cookie","id":"CVE-2025-5947"},"packages":[],"prev":{"headline":"This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.","id":"CVE-2025-5945"},"products":["Infra Monitoring"],"published":"2025-10-14","related":[{"cvss_score":9.8,"headline":"SQL injection in n/a","id":"CVE-2024-32501","kev_date_added":null,"published":"2024-08-23"},{"cvss_score":9.1,"headline":"SQL injection in n/a","id":"CVE-2024-53923","kev_date_added":null,"published":"2025-01-23"},{"cvss_score":9.1,"headline":"SQL injection in n/a","id":"CVE-2024-55573","kev_date_added":null,"published":"2025-01-23"},{"cvss_score":9.1,"headline":"SQL injection in n/a","id":"CVE-2024-33852","kev_date_added":null,"published":"2024-08-23"},{"cvss_score":9.1,"headline":"SQL injection in n/a","id":"CVE-2024-33853","kev_date_added":null,"published":"2024-08-23"},{"cvss_score":9.1,"headline":"SQL injection in n/a","id":"CVE-2024-33854","kev_date_added":null,"published":"2024-08-23"},{"cvss_score":8.8,"headline":"Second order SQL injection available to user with low privilege","id":"CVE-2025-6791","kev_date_added":null,"published":"2025-08-22"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"BSD-3-Clause","name":"Metasploit"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-10-14","vendors":["Centreon"]},"summary":"Privileged users can inject OS commands via poller reload configuration, leading to remote code execution on the monitoring server.","url":"https://insights.sbomify.com/CVE-2025-5946/"}