{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-59460 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-59460 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-59460 is a high-severity vulnerability in SICK AG TLOC100-100 with Firmware \u003c7.1.1, published on 27 Oct 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-59460 and fix it if it is affected.\n\nWhat it is: CVE-2025-59460 is a high-severity vulnerability in SICK AG TLOC100-100 with Firmware \u003c7.1.1, published on 27 Oct 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-59460 in the wild and no public exploit code.\n\nAffected product: SICK AG TLOC100-100 with Firmware \u003c7.1.1. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-59460/ (Markdown: https://insights.sbomify.com/CVE-2025-59460/index.md)","id":"CVE-2025-59460","markdown":"https://insights.sbomify.com/CVE-2025-59460/index.md","name":"CVE-2025-59460","record":{"aliases":["GHSA-qm85-xhq4-w756"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial IoT device","requires_auth":"none","summary":"Default insecure configurations on SICK TLOC100 devices allow unauthorized connections, requiring firmware updates to enforce secure access controls.","user_interaction":"not_required","vuln_class":"misconfiguration"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"SICK AG","cpe":[{"product":"tloc100-100_firmware","vendor":"sick"}],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-1391","name":"Use of Weak Credentials"}],"description":"The system is deployed in its default state, with configuration settings that do not comply with the latest best practices for restricting access. This increases the risk of unauthorised connections.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Unsecure access configuration","id":"CVE-2025-59460","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"misconfiguration","year":"2025"},"n_packages":0,"n_references":6,"next":{"headline":"API does not require authentication","id":"CVE-2025-59461"},"packages":[],"prev":{"headline":"Denial-of-service (DoS) via resource consumption","id":"CVE-2025-59459"},"products":["TLOC100-100 with Firmware \u003c7.1.1","TLOC100-100 with Firmware \u003e=7.1.1"],"published":"2025-10-27","related":[{"cvss_score":7.6,"headline":"API does not require authentication","id":"CVE-2025-59461","kev_date_added":null,"published":"2025-10-27"},{"cvss_score":6.5,"headline":"Denial-of-service (DoS) via delayed or missing client response","id":"CVE-2025-59462","kev_date_added":null,"published":"2025-10-27"},{"cvss_score":5.5,"headline":"Denial-of-service (DoS) via resource consumption","id":"CVE-2025-59459","kev_date_added":null,"published":"2025-10-27"},{"cvss_score":4.3,"headline":"Denial-of-service (DoS) via chunk size mismatch","id":"CVE-2025-59463","kev_date_added":null,"published":"2025-10-27"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-10-27","vendors":["SICK AG"]},"summary":"Default insecure configurations on SICK TLOC100 devices allow unauthorized connections, requiring firmware updates to enforce secure access controls.","url":"https://insights.sbomify.com/CVE-2025-59460/"}