{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-6073 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-6073 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-6073 is a high-severity memory corruption vulnerability in ABB RMC-100, published on 3 Jul 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-6073 and fix it if it is affected.\n\nWhat it is: CVE-2025-6073 is a high-severity memory corruption vulnerability in ABB RMC-100, published on 3 Jul 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-6073 in the wild and no public exploit code.\n\nAffected product: ABB RMC-100. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-6073/ (Markdown: https://insights.sbomify.com/CVE-2025-6073/index.md)","id":"CVE-2025-6073","markdown":"https://insights.sbomify.com/CVE-2025-6073/index.md","name":"CVE-2025-6073","record":{"aliases":["GHSA-rmg9-687h-jx4v"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":true,"product_category":"ABB RMC-100 controller","requires_auth":"none","summary":"Attackers can trigger a stack buffer overflow in MQTTCore via REST interface, potentially leading to code execution on ABB RMC-100 controllers.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"ABB","cpe":[],"cvss":{"score":8.2,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE.\n\nWhen the REST interface is enabled by the user, and an attacker gains access to\nthe control network, and user/password broker authentication is enabled, and\nCVE-2025-6074 is exploited, the attacker can overflow the buffer for username or\npassword.\n\nThis issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Stack Buffer Overflow in MQTTCore","id":"CVE-2025-6073","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Authentication Bypass to the MQTT configuration Web Interface","id":"CVE-2025-6074"},"packages":[],"prev":{"headline":"Stack Buffer Overflow in MQTTCore","id":"CVE-2025-6072"},"products":["RMC-100","RMC-100 LITE"],"published":"2025-07-03","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-07-03","vendors":["ABB"]},"summary":"Attackers can trigger a stack buffer overflow in MQTTCore via REST interface, potentially leading to code execution on ABB RMC-100 controllers.","url":"https://insights.sbomify.com/CVE-2025-6073/"}