{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-60938 exists.","fix":"No fix has been published for CVE-2025-60938 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-60938 is a high-severity command injection vulnerability in n/a, published on 24 Oct 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-60938 and fix it if it is affected.\n\nWhat it is: CVE-2025-60938 is a high-severity command injection vulnerability in n/a, published on 24 Oct 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-60938 exists.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-60938/ (Markdown: https://insights.sbomify.com/CVE-2025-60938/index.md)","id":"CVE-2025-60938","markdown":"https://insights.sbomify.com/CVE-2025-60938/index.md","name":"CVE-2025-60938","record":{"aliases":["GHSA-765w-986x-7c7p"],"analysis":{"component_type":"web_application","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Emoncms energy monitoring","requires_auth":"low_privilege","summary":"Authenticated attackers can execute arbitrary commands via insufficient input validation in the firmware upload feature of Emoncms.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"emoncms","vendor":"openenergymonitor"}],"cvss":{"score":7.5,"severity":"high","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"Emoncms 11.7.3 has a remote code execution vulnerability in the firmware upload feature that allows authenticated users to execute arbitrary commands on the target system. The vulnerability stems from insufficient input validation of user-controlled parameters including filename, port, baud_rate, core, and autoreset within the /admin/upload-custom-firmware endpoint.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":false,"headline":"Command injection in n/a","id":"CVE-2025-60938","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Census CSWeb path traversal","id":"CVE-2025-60946"},"packages":[],"prev":{"headline":"Cross-site scripting in n/a","id":"CVE-2025-60936"},"products":["n/a"],"published":"2025-10-24","related":[{"cvss_score":9.8,"headline":"SQL injection in n/a","id":"CVE-2025-22992","kev_date_added":null,"published":"2025-02-06"},{"cvss_score":6.1,"headline":"Cross-site scripting in n/a","id":"CVE-2025-60936","kev_date_added":null,"published":"2025-10-24"},{"cvss_score":6.1,"headline":"Cross-site scripting in n/a","id":"CVE-2021-26716","kev_date_added":null,"published":"2021-02-21"},{"cvss_score":6.1,"headline":"Cross-site scripting in n/a","id":"CVE-2017-5964","kev_date_added":null,"published":"2017-02-12"},{"cvss_score":5.4,"headline":"Cross-site scripting in Emoncms","id":"CVE-2019-1010008","kev_date_added":null,"published":"2019-07-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-10-24","vendors":["n/a"]},"summary":"Authenticated attackers can execute arbitrary commands via insufficient input validation in the firmware upload feature of Emoncms.","url":"https://insights.sbomify.com/CVE-2025-60938/"}