{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-61740 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-61740 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-61740 is a high-severity authentication bypass vulnerability in Johnson Controls IQ Panels2, 2+, IQHub, IQPanel 4, PowerG, published on 22 Dec 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-61740 and fix it if it is affected.\n\nWhat it is: CVE-2025-61740 is a high-severity authentication bypass vulnerability in Johnson Controls IQ Panels2, 2+, IQHub, IQPanel 4, PowerG, published on 22 Dec 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-61740 in the wild and no public exploit code.\n\nAffected product: Johnson Controls IQ Panels2, 2+, IQHub, IQPanel 4, PowerG. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-61740/ (Markdown: https://insights.sbomify.com/CVE-2025-61740/index.md)","id":"CVE-2025-61740","markdown":"https://insights.sbomify.com/CVE-2025-61740/index.md","name":"CVE-2025-61740","record":{"aliases":["GHSA-r4f7-5v86-4w55"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["denial_of_service","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Security control panel","requires_auth":"none","summary":"Attackers can bypass origin validation to cause denial of service or modify device configuration on Johnson Controls security panels.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"jci","cpe":[],"cvss":{"score":7.2,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:L/SC:L/SI:L/SA:N","version":"4.0"},"cwes":[{"id":"CWE-346","name":"Origin Validation Error"}],"description":"Authentication issue that does not verify the source of a packet which could allow an attacker to create a denial-of-service condition or modify the configuration of the device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Johnson Controls IQ Panels2, 2+, IQHub, IQPanel 4, PowerG Origin Validation Error","id":"CVE-2025-61740","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"Missing authorization in Oracle GraalVM Enterprise Edition","id":"CVE-2025-61748"},"packages":[],"prev":{"headline":"Johnson Controls IQ Panels2, 2+, IQHub, IQPanel 4, PowerG reusing a nonce, key pair in encryption","id":"CVE-2025-61739"},"products":["IQ Panels2, 2+, IQHub, IQPanel 4, PowerG"],"published":"2025-12-22","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-12-22","vendors":["Johnson Controls"]},"summary":"Attackers can bypass origin validation to cause denial of service or modify device configuration on Johnson Controls security panels.","url":"https://insights.sbomify.com/CVE-2025-61740/"}