{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-62765 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-62765 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-62765 is a high-severity vulnerability in General Industrial Controls Lynx+ Gateway, published on 14 Nov 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-62765 and fix it if it is affected.\n\nWhat it is: CVE-2025-62765 is a high-severity vulnerability in General Industrial Controls Lynx+ Gateway, published on 14 Nov 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-62765 in the wild and no public exploit code.\n\nAffected product: General Industrial Controls Lynx+ Gateway. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-62765/ (Markdown: https://insights.sbomify.com/CVE-2025-62765/index.md)","id":"CVE-2025-62765","markdown":"https://insights.sbomify.com/CVE-2025-62765/index.md","name":"CVE-2025-62765","record":{"aliases":["GHSA-9g9v-vcmw-4mp4"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_read","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial Gateway","requires_auth":"none","summary":"An attacker can observe network traffic to obtain sensitive information, including plaintext credentials, from the General Industrial Controls Lynx+ Gateway.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-319","name":"Cleartext Transmission of Sensitive Information"}],"description":"General Industrial Controls Lynx+ Gateway is vulnerable to a cleartext transmission vulnerability that could allow\n an attacker to observe network traffic to obtain sensitive information,\n including plaintext credentials.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"General Industrial Controls Lynx+ Gateway Cleartext Transmission of Sensitive Information","id":"CVE-2025-62765","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site request forgery in M6a","id":"CVE-2025-62771"},"packages":[],"prev":{"headline":"Server-side request forgery in Collaboration","id":"CVE-2025-62763"},"products":["Lynx+ Gateway"],"published":"2025-11-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-11-17","vendors":["General Industrial Controls"]},"summary":"An attacker can observe network traffic to obtain sensitive information, including plaintext credentials, from the General Industrial Controls Lynx+ Gateway.","url":"https://insights.sbomify.com/CVE-2025-62765/"}