{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-63217 exists.","fix":"No fix has been published for CVE-2025-63217 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-63217 is a critical authentication bypass vulnerability in n/a, published on 18 Nov 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-63217 and fix it if it is affected.\n\nWhat it is: CVE-2025-63217 is a critical authentication bypass vulnerability in n/a, published on 18 Nov 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-63217 exists.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-63217/ (Markdown: https://insights.sbomify.com/CVE-2025-63217/index.md)","id":"CVE-2025-63217","markdown":"https://insights.sbomify.com/CVE-2025-63217/index.md","name":"CVE-2025-63217","record":{"aliases":["GHSA-h8mc-vj52-4vxx"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["privilege_escalation","code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Itel DAB MUX","requires_auth":"none","summary":"Attackers can reuse JWT tokens across devices to gain administrative access, leading to full compromise of Itel DAB MUX units.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"id_mux_firmware","vendor":"itel"}],"cvss":{"score":9.8,"severity":"critical","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-288","name":"Authentication Bypass Using an Alternate Path or Channel"}],"description":"The Itel DAB MUX (IDMUX build c041640a) is vulnerable to Authentication Bypass due to improper JWT validation across devices. Attackers can reuse a valid JWT token obtained from one device to authenticate and gain administrative access to any other device running the same firmware, even if the passwords and networks are different. This allows full compromise of affected devices.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Auth bypass in n/a","id":"CVE-2025-63217","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"Missing authorization in n/a","id":"CVE-2025-63218"},"packages":[],"prev":{"headline":"Auth bypass in n/a","id":"CVE-2025-63216"},"products":["n/a"],"published":"2025-11-18","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-11-19","vendors":["n/a"]},"summary":"Attackers can reuse JWT tokens across devices to gain administrative access, leading to full compromise of Itel DAB MUX units.","url":"https://insights.sbomify.com/CVE-2025-63217/"}