# CVE-2025-66052: Command injection in Vivotek IP7137 cameras

> Attackers can execute arbitrary commands on Vivotek IP7137 cameras via unsanitized NTP parameters, exploiting default administrative access.

- **Severity:** High 8.6 (`CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N`)
- **Exploited in the wild:** Not known
- **Login needed:** An administrator
- **Attackable:** Over the internet
- **Victim action needed:** Not needed
- **Fix available:** No
- **Published:** 9 Jan 2026
- **Updated:** 9 Jan 2026
- **Also known as:** GHSA-6hj7-3vmc-gm54

## What is CVE-2025-66052?

CVE-2025-66052 is a high-severity command injection vulnerability in Vivotek IP7137, published on 9 Jan 2026. An attacker needs administrator access to exploit it, with no action from the victim.

### Official description

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default, 
The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.

Weakness: CWE-78 (Improper Neutralization of Special Elements used in an OS Command)

## Which versions are affected by CVE-2025-66052?

It affects 1 product.


Products: Vivotek Ip7137 Firmware.

## How do I fix CVE-2025-66052?

No fix has been published for CVE-2025-66052 yet. Limit exposure of the affected software until one is available.

## Is CVE-2025-66052 being exploited?

There is no known exploitation of CVE-2025-66052 in the wild and no public exploit code.

## Other vulnerabilities in Vivotek IP7137

- [CVE-2025-66050](https://insights.sbomify.com/CVE-2025-66050/): No password set for administrative account in Vivotek IP7137 cameras (critical 9.3)
- [CVE-2025-66049](https://insights.sbomify.com/CVE-2025-66049/): Unprotected RTSP stream in Vivotek IP7137 cameras (high 8.7)
- [CVE-2025-66051](https://insights.sbomify.com/CVE-2025-66051/): Path traversal in Vivotek IP7137 cameras (medium 6.9)

## Fix prompt for AI coding agents

```text
Check this codebase for CVE-2025-66052 and fix it if it is affected.

What it is: CVE-2025-66052 is a high-severity command injection vulnerability in Vivotek IP7137, published on 9 Jan 2026. An attacker needs administrator access to exploit it, with no action from the victim.
Exploitation: There is no known exploitation of CVE-2025-66052 in the wild and no public exploit code.

Affected product: Vivotek IP7137. No package-level version data is available, so check the vendor advisory linked from the reference page.

Task:
1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.
2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.
3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.
4. Run the tests and summarise what changed and why.
5. If nothing in the project is affected, say so and change nothing.

Reference: https://insights.sbomify.com/CVE-2025-66052/ (Markdown: https://insights.sbomify.com/CVE-2025-66052/index.md)
```

## Sources

- CVE record: https://www.cve.org/CVERecord?id=CVE-2025-66052
- NVD: https://nvd.nist.gov/vuln/detail/CVE-2025-66052
- OSV: https://osv.dev/vulnerability/CVE-2025-66052

---
From sbomify Insights: https://insights.sbomify.com/CVE-2025-66052/