{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-6788 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-6788 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-6788 is a medium-severity vulnerability in Schneider Electric EcoStruxure™ Power Monitoring Expert, published on 11 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-6788 and fix it if it is affected.\n\nWhat it is: CVE-2025-6788 is a medium-severity vulnerability in Schneider Electric EcoStruxure™ Power Monitoring Expert, published on 11 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-6788 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure™ Power Monitoring Expert. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-6788/ (Markdown: https://insights.sbomify.com/CVE-2025-6788/index.md)","id":"CVE-2025-6788","markdown":"https://insights.sbomify.com/CVE-2025-6788/index.md","name":"CVE-2025-6788","record":{"aliases":["GHSA-q2rf-262f-hfr2"],"analysis":{"component_type":"web_application","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Power Monitoring Expert","requires_auth":"low_privilege","summary":"Authenticated users can access TGML diagram resources they should not see, leading to unauthorized information disclosure in Schneider Electric power monitoring systems.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-668","name":"Exposure of Resource to Wrong Sphere"}],"description":"A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that exposes TGML diagram resources\nto the wrong control sphere, providing other authenticated users with potentially inappropriate access to TGML\ndiagrams.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in EcoStruxure™ Power Monitoring Expert","id":"CVE-2025-6788","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"QSM \u003c 10.2.3 - Template Creation via CSRF","id":"CVE-2025-6790"},"packages":[],"prev":{"headline":"Smart Docs \u003c= 1.1.0 - Authenticated (Contributor+) Stored Cross-Site Scripting","id":"CVE-2025-6787"},"products":["EcoStruxure™ Power Monitoring Expert","EcoStruxure™ Power Operation Advanced Reporting and Dashboards Module"],"published":"2025-07-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-07-22","vendors":["Schneider Electric"]},"summary":"Authenticated users can access TGML diagram resources they should not see, leading to unauthorized information disclosure in Schneider Electric power monitoring systems.","url":"https://insights.sbomify.com/CVE-2025-6788/"}