{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-68915 exists.","fix":"No fix has been published for CVE-2025-68915 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-68915 is a medium-severity cross-site scripting vulnerability in Riello NetMan, published on 24 Dec 2025. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-68915 and fix it if it is affected.\n\nWhat it is: CVE-2025-68915 is a medium-severity cross-site scripting vulnerability in Riello NetMan, published on 24 Dec 2025. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-68915 exists.\n\nAffected product: Riello NetMan. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-68915/ (Markdown: https://insights.sbomify.com/CVE-2025-68915/index.md)","id":"CVE-2025-68915","markdown":"https://insights.sbomify.com/CVE-2025-68915/index.md","name":"CVE-2025-68915","record":{"aliases":["GHSA-4hfm-3834-w3r8"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"UPS management interface","requires_auth":"high_privilege","summary":"An attacker can inject malicious scripts into the login banner of Riello UPS NetMan 208 devices, potentially compromising user sessions.","user_interaction":"not_required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"netman_208","vendor":"riello-ups"}],"cvss":{"score":5.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"Riello UPS NetMan 208 Application before 1.12 allows cgi-bin/loginbanner_w.cgi XSS via a crafted banner.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Cross-site scripting in NetMan","id":"CVE-2025-68915","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in NetMan","id":"CVE-2025-68916"},"packages":[],"prev":{"headline":"SQL injection in NetMan","id":"CVE-2025-68914"},"products":["NetMan"],"published":"2025-12-24","related":[{"cvss_score":9.1,"headline":"Path traversal in NetMan","id":"CVE-2025-68916","kev_date_added":null,"published":"2025-12-24"},{"cvss_score":6.5,"headline":"SQL injection in NetMan","id":"CVE-2025-68914","kev_date_added":null,"published":"2025-12-24"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-12-24","vendors":["Riello"]},"summary":"An attacker can inject malicious scripts into the login banner of Riello UPS NetMan 208 devices, potentially compromising user sessions.","url":"https://insights.sbomify.com/CVE-2025-68915/"}