{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-7116 exists.","fix":"No fix has been published for CVE-2025-7116 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-7116 is a high-severity memory corruption vulnerability in UTT 进取 750W, published on 7 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-7116 and fix it if it is affected.\n\nWhat it is: CVE-2025-7116 is a high-severity memory corruption vulnerability in UTT 进取 750W, published on 7 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-7116 exists.\n\nAffected product: UTT 进取 750W. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-7116/ (Markdown: https://insights.sbomify.com/CVE-2025-7116/index.md)","id":"CVE-2025-7116","markdown":"https://insights.sbomify.com/CVE-2025-7116/index.md","name":"CVE-2025-7116","record":{"aliases":["GHSA-j2pg-vqh3-373c"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"UTT wireless router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a buffer overflow in the UTT 750W router via the SSID parameter, potentially leading to code execution or service disruption.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"750w_firmware","vendor":"utt"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A vulnerability classified as critical has been found in UTT 进取 750W up to 3.2.2-191225. This affects an unknown part of the file /goform/Fast_wireless_conf. The manipulation of the argument ssid leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"UTT 进取 750W Fast_wireless_conf buffer overflow","id":"CVE-2025-7116","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"UTT HiPER 840G websWhiteList buffer overflow","id":"CVE-2025-7117"},"packages":[],"prev":{"headline":"rowboatlabs rowboat Session route.ts PUT missing authentication","id":"CVE-2025-7115"},"products":["进取 750W"],"published":"2025-07-07","related":[{"cvss_score":9.3,"headline":"UTT 进取 750W API setSysAdm strcpy buffer overflow","id":"CVE-2025-6098","kev_date_added":null,"published":"2025-06-16"},{"cvss_score":8.7,"headline":"UTT 750W formPictureUrl buffer overflow","id":"CVE-2025-10172","kev_date_added":null,"published":"2025-09-09"},{"cvss_score":6.9,"headline":"UTT 进取 750W formPdbUpConfig system command injection","id":"CVE-2025-13442","kev_date_added":null,"published":"2025-11-20"},{"cvss_score":6.9,"headline":"UTT 进取 750W Administrator Password setSysAdm formDefineManagement unverified password change","id":"CVE-2025-6097","kev_date_added":null,"published":"2025-06-16"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-07-07","vendors":["UTT"]},"summary":"Remote attackers can trigger a buffer overflow in the UTT 750W router via the SSID parameter, potentially leading to code execution or service disruption.","url":"https://insights.sbomify.com/CVE-2025-7116/"}