{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-7376 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-7376 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-7376 is a medium-severity path traversal vulnerability in Mitsubishi Electric Corporation AnalytiX, published on 6 Aug 2025. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-7376 and fix it if it is affected.\n\nWhat it is: CVE-2025-7376 is a medium-severity path traversal vulnerability in Mitsubishi Electric Corporation AnalytiX, published on 6 Aug 2025. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-7376 in the wild and no public exploit code.\n\nAffected product: Mitsubishi Electric Corporation AnalytiX. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-7376/ (Markdown: https://insights.sbomify.com/CVE-2025-7376/index.md)","id":"CVE-2025-7376","markdown":"https://insights.sbomify.com/CVE-2025-7376/index.md","name":"CVE-2025-7376","record":{"aliases":["GHSA-27f5-vx56-mg6g"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_modify","denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SCADA HMI software","requires_auth":"low_privilege","summary":"Local attackers can overwrite arbitrary files via symbolic links, causing denial of service on systems running affected Mitsubishi SCADA software.","user_interaction":"required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Mitsubishi","cpe":[],"cvss":{"score":5.9,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-64","name":"Windows Shortcut Following (.LNK)"}],"description":"Windows Shortcut Following (.LNK) vulnerability in multiple processes of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric GENESIS version 11.00, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95, and Mitsubishi Electric Iconics Digital Solutions GENESIS version 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the processes of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in AnalytiX","id":"CVE-2025-7376","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2025"},"n_packages":0,"n_references":3,"next":{"headline":"An improper input validation vulnerability was found on manipulating configuration of ADM","id":"CVE-2025-7378"},"packages":[],"prev":{"headline":"Unauthenticated Denial-of-Service Vulnerability in Omada EAP610","id":"CVE-2025-7375"},"products":["AnalytiX","GENESIS","GENESIS64","Hyper Historian","ICONICS Suite","IoTWorX","MC Works64","MobileHMI"],"published":"2025-08-06","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-04-09","vendors":["Mitsubishi Electric Corporation","Mitsubishi Electric Iconics Digital Solutions"]},"summary":"Local attackers can overwrite arbitrary files via symbolic links, causing denial of service on systems running affected Mitsubishi SCADA software.","url":"https://insights.sbomify.com/CVE-2025-7376/"}