{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-7529 exists.","fix":"No fix has been published for CVE-2025-7529 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-7529 is a high-severity memory corruption vulnerability in Tenda Fh1202 Firmware, published on 13 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-7529 and fix it if it is affected.\n\nWhat it is: CVE-2025-7529 is a high-severity memory corruption vulnerability in Tenda Fh1202 Firmware, published on 13 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-7529 exists.\n\nAffected product: Tenda Fh1202 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-7529/ (Markdown: https://insights.sbomify.com/CVE-2025-7529/index.md)","id":"CVE-2025-7529","markdown":"https://insights.sbomify.com/CVE-2025-7529/index.md","name":"CVE-2025-7529","record":{"aliases":["GHSA-m3f6-854w-wp36"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda FH1202 router","requires_auth":"low_privilege","summary":"A remote attacker can trigger a stack-based buffer overflow in the Tenda FH1202 router's Natlimit function, potentially leading to arbitrary code execution.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"fh1202_firmware","vendor":"tenda"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A vulnerability classified as critical was found in Tenda FH1202 1.2.0.14(408). Affected by this vulnerability is the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda FH1202 Natlimit fromNatlimit stack-based overflow","id":"CVE-2025-7529","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:fh1202_firmware","products":["tenda:fh1202_firmware"],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"Tenda FH1202 PPTPDClient fromPptpUserAdd stack-based overflow","id":"CVE-2025-7530"},"packages":[],"prev":{"headline":"Tenda FH1202 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow","id":"CVE-2025-7528"},"products":["FH1202"],"published":"2025-07-13","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-30584","kev_date_added":null,"published":"2024-03-28"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-30587","kev_date_added":null,"published":"2024-03-28"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-30589","kev_date_added":null,"published":"2024-03-28"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-30593","kev_date_added":null,"published":"2024-03-28"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-30595","kev_date_added":null,"published":"2024-03-28"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-30596","kev_date_added":null,"published":"2024-03-28"},{"cvss_score":8.8,"headline":"Memory corruption in n/a","id":"CVE-2024-30591","kev_date_added":null,"published":"2024-03-28"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-07-14","vendors":["Tenda"]},"summary":"A remote attacker can trigger a stack-based buffer overflow in the Tenda FH1202 router's Natlimit function, potentially leading to arbitrary code execution.","url":"https://insights.sbomify.com/CVE-2025-7529/"}