{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-7549 exists.","fix":"No fix has been published for CVE-2025-7549 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-7549 is a high-severity memory corruption vulnerability in Tenda FH1201, published on 13 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-7549 and fix it if it is affected.\n\nWhat it is: CVE-2025-7549 is a high-severity memory corruption vulnerability in Tenda FH1201, published on 13 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-7549 exists.\n\nAffected product: Tenda FH1201. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-7549/ (Markdown: https://insights.sbomify.com/CVE-2025-7549/index.md)","id":"CVE-2025-7549","markdown":"https://insights.sbomify.com/CVE-2025-7549/index.md","name":"CVE-2025-7549","record":{"aliases":["GHSA-vqvf-37v7-h2r7"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda FH1201 router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda FH1201 router's L7Prot form, potentially leading to arbitrary code execution.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"fh1201_firmware","vendor":"tenda"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A vulnerability was found in Tenda FH1201 1.2.0.14(408) and classified as critical. This issue affects the function frmL7ProtForm of the file /goform/L7Prot. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda FH1201 L7Prot frmL7ProtForm stack-based overflow","id":"CVE-2025-7549","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":6,"next":{"headline":"Tenda FH1201 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow","id":"CVE-2025-7550"},"packages":[],"prev":{"headline":"Tenda FH1201 SafeEmailFilter formSafeEmailFilter stack-based overflow","id":"CVE-2025-7548"},"products":["FH1201"],"published":"2025-07-13","related":[{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2024-42947","kev_date_added":null,"published":"2024-08-15"},{"cvss_score":8.7,"headline":"Tenda FH1201 Parameter WrlclientSet stack-based overflow","id":"CVE-2026-5045","kev_date_added":null,"published":"2026-03-29"},{"cvss_score":8.7,"headline":"Tenda FH1201 Parameter WrlExtraSet formWrlExtraSet stack-based overflow","id":"CVE-2026-5046","kev_date_added":null,"published":"2026-03-29"},{"cvss_score":8.7,"headline":"Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow","id":"CVE-2025-14994","kev_date_added":null,"published":"2025-12-21"},{"cvss_score":8.7,"headline":"Tenda FH1201 SetIpBind sprintf stack-based overflow","id":"CVE-2025-14995","kev_date_added":null,"published":"2025-12-21"},{"cvss_score":8.7,"headline":"Tenda FH1201 SafeEmailFilter formSafeEmailFilter stack-based overflow","id":"CVE-2025-7548","kev_date_added":null,"published":"2025-07-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-07-14","vendors":["Tenda"]},"summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda FH1201 router's L7Prot form, potentially leading to arbitrary code execution.","url":"https://insights.sbomify.com/CVE-2025-7549/"}