# CVE-2025-7597: Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow

> A remote attacker can trigger a stack-based buffer overflow in the Tenda AX1803 router's MAC filter configuration interface to potentially execute arbitrary code.

- **Severity:** High 8.7 (`CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P`)
- **Exploited in the wild:** Not known
- **Login needed:** Any signed-in user
- **Attackable:** Over the internet
- **Victim action needed:** Not needed
- **Fix available:** No
- **Published:** 14 Jul 2025
- **Updated:** 14 Jul 2025
- **Also known as:** GHSA-wpgg-p8v9-9qg3

## What is CVE-2025-7597?

CVE-2025-7597 is a high-severity memory corruption vulnerability in Tenda Ax1803 Firmware, published on 14 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim.

### Official description

A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Weakness: CWE-121 (Stack-based Buffer Overflow), CWE-119 (Improper Restriction of Operations within the Bounds of a Memory Buffer)

## Which versions are affected by CVE-2025-7597?

It affects 1 product.


Products: Tenda Ax1803 Firmware.

## How do I fix CVE-2025-7597?

No fix has been published for CVE-2025-7597 yet. Limit exposure of the affected software until one is available.

## Is CVE-2025-7597 being exploited?

It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-7597 exists.

## Other vulnerabilities in Tenda Ax1803 Firmware

- [CVE-2024-30620](https://insights.sbomify.com/CVE-2024-30620/): Memory corruption in n/a (critical 9.8)
- [CVE-2023-51952](https://insights.sbomify.com/CVE-2023-51952/): Memory corruption in n/a (critical 9.8)
- [CVE-2023-51953](https://insights.sbomify.com/CVE-2023-51953/): Memory corruption in n/a (critical 9.8)
- [CVE-2023-51954](https://insights.sbomify.com/CVE-2023-51954/): Memory corruption in n/a (critical 9.8)
- [CVE-2023-51956](https://insights.sbomify.com/CVE-2023-51956/): Memory corruption in n/a (critical 9.8)

## Fix prompt for AI coding agents

```text
Check this codebase for CVE-2025-7597 and fix it if it is affected.

What it is: CVE-2025-7597 is a high-severity memory corruption vulnerability in Tenda Ax1803 Firmware, published on 14 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim.
Exploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-7597 exists.

Affected product: Tenda Ax1803 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.

Task:
1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.
2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.
3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.
4. Run the tests and summarise what changed and why.
5. If nothing in the project is affected, say so and change nothing.

Reference: https://insights.sbomify.com/CVE-2025-7597/ (Markdown: https://insights.sbomify.com/CVE-2025-7597/index.md)
```

## Sources

- CVE record: https://www.cve.org/CVERecord?id=CVE-2025-7597
- NVD: https://nvd.nist.gov/vuln/detail/CVE-2025-7597
- OSV: https://osv.dev/vulnerability/CVE-2025-7597

---
From sbomify Insights: https://insights.sbomify.com/CVE-2025-7597/
Summaries are generated and may contain mistakes; the official description above is the record.
