{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-7705 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-7705 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-7705 is a high-severity authentication bypass vulnerability in ABB Switch Actuator 4 DU-83330, published on 22 Jul 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-7705 and fix it if it is affected.\n\nWhat it is: CVE-2025-7705 is a high-severity authentication bypass vulnerability in ABB Switch Actuator 4 DU-83330, published on 22 Jul 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-7705 in the wild and no public exploit code.\n\nAffected product: ABB Switch Actuator 4 DU-83330. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-7705/ (Markdown: https://insights.sbomify.com/CVE-2025-7705/index.md)","id":"CVE-2025-7705","markdown":"https://insights.sbomify.com/CVE-2025-7705/index.md","name":"CVE-2025-7705","record":{"aliases":["GHSA-7cwr-3892-8m78"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"ABB Switch Actuator","requires_auth":"none","summary":"Attackers can bypass authentication on ABB Switch Actuators because compatibility mode is enabled by default, allowing unauthorized access.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"ABB","cpe":[],"cvss":{"score":8.6,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0"},"cwes":[{"id":"CWE-489","name":"Active Debug Code"}],"description":": Active Debug Code vulnerability in ABB Switch Actuator 4 DU-83330, ABB Switch actuator, door/light 4 DU -83330-500.This issue affects Switch Actuator 4 DU-83330: All Versions; Switch actuator, door/light 4 DU -83330-500: All Versions.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Authentication bypass due to compatibility mode enabled by default","id":"CVE-2025-7705","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Improper Access Control in TUBITAK BILGEM's Liderahenk","id":"CVE-2025-7706"},"packages":[],"prev":{"headline":"Supermicro BMC SMASH services has a Stack-based buffer overflow vulnerability","id":"CVE-2025-7704"},"products":["Switch Actuator 4 DU-83330","Switch actuator, door/light 4 DU -83330-500"],"published":"2025-07-22","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-07-22","vendors":["ABB"]},"summary":"Attackers can bypass authentication on ABB Switch Actuators because compatibility mode is enabled by default, allowing unauthorized access.","url":"https://insights.sbomify.com/CVE-2025-7705/"}