{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-7883 exists.","fix":"No fix has been published for CVE-2025-7883 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-7883 is a high-severity command injection vulnerability in Eluktronics Control Center, published on 20 Jul 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-7883 and fix it if it is affected.\n\nWhat it is: CVE-2025-7883 is a high-severity command injection vulnerability in Eluktronics Control Center, published on 20 Jul 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-7883 exists.\n\nAffected product: Eluktronics Control Center. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-7883/ (Markdown: https://insights.sbomify.com/CVE-2025-7883/index.md)","id":"CVE-2025-7883","markdown":"https://insights.sbomify.com/CVE-2025-7883/index.md","name":"CVE-2025-7883","record":{"aliases":["GHSA-4m3f-8qmg-8c9p"],"analysis":{"component_type":"desktop_application","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Eluktronics Control Center","requires_auth":"low_privilege","summary":"Local attackers can execute arbitrary commands via the PowerShell script handler in Eluktronics Control Center, leading to code execution.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"control_center","vendor":"eluktronics"}],"cvss":{"score":8.5,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"description":"A vulnerability classified as critical has been found in Eluktronics Control Center 5.23.51.41. Affected is an unknown function of the file \\AiStoneService\\MyControlCenter\\Command of the component Powershell Script Handler. The manipulation leads to command injection. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Eluktronics Control Center Powershell Script Command command injection","id":"CVE-2025-7883","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2025"},"n_packages":0,"n_references":4,"next":{"headline":"Eluktronics Control Center REG File data authenticity","id":"CVE-2025-7884"},"packages":[],"prev":{"headline":"Mercusys MW301R Login excessive authentication","id":"CVE-2025-7882"},"products":["Control Center"],"published":"2025-07-20","related":[{"cvss_score":4.8,"headline":"Eluktronics Control Center REG File data authenticity","id":"CVE-2025-7884","kev_date_added":null,"published":"2025-07-20"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-07-21","vendors":["Eluktronics"]},"summary":"Local attackers can execute arbitrary commands via the PowerShell script handler in Eluktronics Control Center, leading to code execution.","url":"https://insights.sbomify.com/CVE-2025-7883/"}