{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-7884 exists.","fix":"No fix has been published for CVE-2025-7884 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-7884 is a medium-severity vulnerability in Eluktronics Control Center, published on 20 Jul 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-7884 and fix it if it is affected.\n\nWhat it is: CVE-2025-7884 is a medium-severity vulnerability in Eluktronics Control Center, published on 20 Jul 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-7884 exists.\n\nAffected product: Eluktronics Control Center. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-7884/ (Markdown: https://insights.sbomify.com/CVE-2025-7884/index.md)","id":"CVE-2025-7884","markdown":"https://insights.sbomify.com/CVE-2025-7884/index.md","name":"CVE-2025-7884","record":{"aliases":["GHSA-f4pg-w29q-pm6g"],"analysis":{"component_type":"desktop_application","fix_type":"no_fix_stated","impacts":["privilege_escalation","code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Eluktronics Control Center","requires_auth":"low_privilege","summary":"Local attackers can bypass data authenticity checks in the REG file handler to potentially execute arbitrary code or escalate privileges.","user_interaction":"not_required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"control_center","vendor":"eluktronics"}],"cvss":{"score":4.8,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-345","name":"Insufficient Verification of Data Authenticity"}],"description":"A vulnerability classified as problematic was found in Eluktronics Control Center 5.23.51.41. Affected by this vulnerability is an unknown functionality of the component REG File Handler. The manipulation leads to insufficient verification of data authenticity. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Eluktronics Control Center REG File data authenticity","id":"CVE-2025-7884","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2025"},"n_packages":0,"n_references":4,"next":{"headline":"Huashengdun WebSSH Login Page cross site scripting","id":"CVE-2025-7885"},"packages":[],"prev":{"headline":"Eluktronics Control Center Powershell Script Command command injection","id":"CVE-2025-7883"},"products":["Control Center"],"published":"2025-07-20","related":[{"cvss_score":8.5,"headline":"Eluktronics Control Center Powershell Script Command command injection","id":"CVE-2025-7883","kev_date_added":null,"published":"2025-07-20"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-07-21","vendors":["Eluktronics"]},"summary":"Local attackers can bypass data authenticity checks in the REG file handler to potentially execute arbitrary code or escalate privileges.","url":"https://insights.sbomify.com/CVE-2025-7884/"}