{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-8017 exists.","fix":"No fix has been published for CVE-2025-8017 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-8017 is a high-severity memory corruption vulnerability in Tenda Ac7 Firmware, published on 22 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-8017 and fix it if it is affected.\n\nWhat it is: CVE-2025-8017 is a high-severity memory corruption vulnerability in Tenda Ac7 Firmware, published on 22 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-8017 exists.\n\nAffected product: Tenda Ac7 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-8017/ (Markdown: https://insights.sbomify.com/CVE-2025-8017/index.md)","id":"CVE-2025-8017","markdown":"https://insights.sbomify.com/CVE-2025-8017/index.md","name":"CVE-2025-8017","record":{"aliases":["GHSA-x7rp-rm5v-55v3"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC7 router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC7 router's httpd service via the deviceList argument, potentially leading to code execution.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac7_firmware","vendor":"tenda"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda AC7 httpd setMacFilterCfg formSetMacFilterCfg stack-based overflow","id":"CVE-2025-8017","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac7_firmware","products":["tenda:ac7_firmware"],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"code-projects Food Ordering Review System reservation_page.php sql injection","id":"CVE-2025-8018"},"packages":[],"prev":{"headline":"Shortcodes Ultimate \u003c= 7.4.2 - Authenticated (Author+) Stored Cross-Site Scripting via Image Title and Slide Link","id":"CVE-2025-8015"},"products":["AC7"],"published":"2025-07-22","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51843","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51844","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51845","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51846","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29135","kev_date_added":null,"published":"2025-03-24"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29137","kev_date_added":null,"published":"2025-03-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-32301","kev_date_added":null,"published":"2024-04-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-07-22","vendors":["Tenda"]},"summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC7 router's httpd service via the deviceList argument, potentially leading to code execution.","url":"https://insights.sbomify.com/CVE-2025-8017/"}