{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-8178 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-8178 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-8178 is a high-severity memory corruption vulnerability in Tenda Ac10 Firmware, published on 26 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-8178 and fix it if it is affected.\n\nWhat it is: CVE-2025-8178 is a high-severity memory corruption vulnerability in Tenda Ac10 Firmware, published on 26 Jul 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-8178 in the wild and no public exploit code.\n\nAffected product: Tenda Ac10 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-8178/ (Markdown: https://insights.sbomify.com/CVE-2025-8178/index.md)","id":"CVE-2025-8178","markdown":"https://insights.sbomify.com/CVE-2025-8178/index.md","name":"CVE-2025-8178","record":{"aliases":["GHSA-cqgq-v935-xwv5"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC10 router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a heap-based buffer overflow in the Tenda AC10 router via the device1D parameter, potentially leading to code execution or service disruption.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac10_firmware","vendor":"tenda"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-122","name":"Heap-based Buffer Overflow"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A vulnerability classified as critical has been found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /goform/RequestsProcessLaid. The manipulation of the argument device1D leads to heap-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Tenda AC10 RequestsProcessLaid heap-based overflow","id":"CVE-2025-8178","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac10_firmware","products":["tenda:ac10_firmware"],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"PHPGurukul Local Services Search Engine Management System changeimage.php sql injection","id":"CVE-2025-8179"},"packages":[],"prev":{"headline":"LibTIFF thumbnail.c setrow buffer overflow","id":"CVE-2025-8177"},"products":["AC10"],"published":"2025-07-26","related":[{"cvss_score":9.8,"headline":"Tenda AC7, AC9, and AC10 Routers Command Injection","id":"CVE-2018-14558","kev_date_added":"2021-11-03","published":"2018-10-30"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-67073","kev_date_added":null,"published":"2025-12-17"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-45779","kev_date_added":null,"published":"2025-05-12"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-25456","kev_date_added":null,"published":"2025-04-15"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-25674","kev_date_added":null,"published":"2025-02-20"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2025-25675","kev_date_added":null,"published":"2025-02-20"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-45479","kev_date_added":null,"published":"2023-11-29"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-07-28","vendors":["Tenda"]},"summary":"Remote attackers can trigger a heap-based buffer overflow in the Tenda AC10 router via the device1D parameter, potentially leading to code execution or service disruption.","url":"https://insights.sbomify.com/CVE-2025-8178/"}