{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-8320 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-8320 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-8320 is a high-severity memory corruption vulnerability in Tesla Wall Connector, published on 30 Jul 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-8320 and fix it if it is affected.\n\nWhat it is: CVE-2025-8320 is a high-severity memory corruption vulnerability in Tesla Wall Connector, published on 30 Jul 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-8320 in the wild and no public exploit code.\n\nAffected product: Tesla Wall Connector. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-8320/ (Markdown: https://insights.sbomify.com/CVE-2025-8320/index.md)","id":"CVE-2025-8320","markdown":"https://insights.sbomify.com/CVE-2025-8320/index.md","name":"CVE-2025-8320","record":{"aliases":["GHSA-xgh5-7gp7-7mg3"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Tesla Wall Connector","requires_auth":"none","summary":"Network-adjacent attackers can execute arbitrary code on Tesla Wall Connector devices via improper validation of the HTTP Content-Length header.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"zdi","cpe":[{"product":"wall_connector_firmware","vendor":"tesla"}],"cvss":{"score":8.8,"severity":"high","source":"cna","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-1284","name":"Improper Validation of Specified Quantity in Input"}],"description":"Tesla Wall Connector Content-Length Header Improper Input Validation Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Tesla Wall Connector devices. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the parsing of the HTTP Content-Length header. The issue results from the lack of proper validation of user-supplied data, which can result in memory access past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26300.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Tesla Wall Connector Content-Length Header Improper Input Validation Remote Code Execution Vulnerability","id":"CVE-2025-8320","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Tesla Wall Connector Firmware Downgrade Vulnerability","id":"CVE-2025-8321"},"packages":[],"prev":{"headline":"Cross-site scripting in Barracuda Message Archiver","id":"CVE-2025-8319"},"products":["Wall Connector"],"published":"2025-07-30","related":[{"cvss_score":6.8,"headline":"Tesla Wall Connector Firmware Downgrade Vulnerability","id":"CVE-2025-8321","kev_date_added":null,"published":"2025-07-30"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-07-30","vendors":["Tesla"]},"summary":"Network-adjacent attackers can execute arbitrary code on Tesla Wall Connector devices via improper validation of the HTTP Content-Length header.","url":"https://insights.sbomify.com/CVE-2025-8320/"}