{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-8428 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-8428 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-8428 is a medium-severity cross-site scripting vulnerability in Centreon Centreon Web, published on 14 Oct 2025. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-8428 and fix it if it is affected.\n\nWhat it is: CVE-2025-8428 is a medium-severity cross-site scripting vulnerability in Centreon Centreon Web, published on 14 Oct 2025. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-8428 in the wild and no public exploit code.\n\nAffected product: Centreon Centreon Web. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-8428/ (Markdown: https://insights.sbomify.com/CVE-2025-8428/index.md)","id":"CVE-2025-8428","markdown":"https://insights.sbomify.com/CVE-2025-8428/index.md","name":"CVE-2025-8428","record":{"aliases":["GHSA-mw2j-cm2r-g4x9"],"analysis":{"component_type":"web_application","fix_type":"upgrade","impacts":["code_execution","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Centreon Infra Monitoring","requires_auth":"low_privilege","summary":"Attackers can inject malicious scripts via the HTTP loader widget, potentially compromising user sessions and data in Centreon Infra Monitoring.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Centreon","cpe":[{"product":"centreon_web","vendor":"centreon"}],"cvss":{"score":6.8,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (HTTP Loader widget modules) allows Stored XSS.This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":false,"headline":"XSS found in the HTTP loader widget","id":"CVE-2025-8428","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"centreon:centreon_web","products":["centreon:centreon_web"],"type":"xss","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"A user with elevated privileges can inject XSS in the ACL Action access configuration page","id":"CVE-2025-8429"},"packages":[],"prev":{"headline":"Cross-site scripting in Beaver Builder Plugin (Starter Version)","id":"CVE-2025-8427"},"products":["Infra Monitoring"],"published":"2025-10-14","related":[{"cvss_score":9.8,"headline":"SQL injection in n/a","id":"CVE-2024-32501","kev_date_added":null,"published":"2024-08-23"},{"cvss_score":9.1,"headline":"SQL injection in n/a","id":"CVE-2024-53923","kev_date_added":null,"published":"2025-01-23"},{"cvss_score":9.1,"headline":"SQL injection in n/a","id":"CVE-2024-55573","kev_date_added":null,"published":"2025-01-23"},{"cvss_score":9.1,"headline":"SQL injection in n/a","id":"CVE-2024-33852","kev_date_added":null,"published":"2024-08-23"},{"cvss_score":9.1,"headline":"SQL injection in n/a","id":"CVE-2024-33853","kev_date_added":null,"published":"2024-08-23"},{"cvss_score":9.1,"headline":"SQL injection in n/a","id":"CVE-2024-33854","kev_date_added":null,"published":"2024-08-23"},{"cvss_score":8.8,"headline":"Second order SQL injection available to user with low privilege","id":"CVE-2025-6791","kev_date_added":null,"published":"2025-08-22"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-10-14","vendors":["Centreon"]},"summary":"Attackers can inject malicious scripts via the HTTP loader widget, potentially compromising user sessions and data in Centreon Infra Monitoring.","url":"https://insights.sbomify.com/CVE-2025-8428/"}