{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-8703 exists.","fix":"No fix has been published for CVE-2025-8703 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-8703 is a medium-severity SQL injection vulnerability in Wanzhou WOES Intelligent Optimization Energy Saving System, published on 8 Aug 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-8703 and fix it if it is affected.\n\nWhat it is: CVE-2025-8703 is a medium-severity SQL injection vulnerability in Wanzhou WOES Intelligent Optimization Energy Saving System, published on 8 Aug 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-8703 exists.\n\nAffected product: Wanzhou WOES Intelligent Optimization Energy Saving System. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-8703/ (Markdown: https://insights.sbomify.com/CVE-2025-8703/index.md)","id":"CVE-2025-8703","markdown":"https://insights.sbomify.com/CVE-2025-8703/index.md","name":"CVE-2025-8703","record":{"aliases":["GHSA-phw8-rj5q-c9qv"],"analysis":{"component_type":"web_application","fix_type":"no_fix_stated","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Energy saving system","requires_auth":"low_privilege","summary":"Remote attackers can exploit SQL injection in the Environmental Real-Time Data Module to read or modify database contents.","user_interaction":"not_required","vuln_class":"sql_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"woes_intelligent_optimization_energy_saving_system","vendor":"wanzhou"}],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-89","name":"Improper Neutralization of Special Elements used in an SQL Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"description":"A vulnerability classified as critical was found in Wanzhou WOES Intelligent Optimization Energy Saving System 1.0. This vulnerability affects unknown code of the file /WEAS_HomePage/GetAreaTrendChartData of the component Environmental Real-Time Data Module. The manipulation of the argument energyId leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"SQL injection in WOES Intelligent Optimization Energy Saving System","id":"CVE-2025-8703","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"sql_injection","year":"2025"},"n_packages":0,"n_references":4,"next":{"headline":"SQL injection in WOES Intelligent Optimization Energy Saving System","id":"CVE-2025-8704"},"packages":[],"prev":{"headline":"SQL injection in WOES Intelligent Optimization Energy Saving System","id":"CVE-2025-8702"},"products":["WOES Intelligent Optimization Energy Saving System"],"published":"2025-08-08","related":[{"cvss_score":5.3,"headline":"SQL injection in WOES Intelligent Optimization Energy Saving System","id":"CVE-2025-8704","kev_date_added":null,"published":"2025-08-08"},{"cvss_score":5.3,"headline":"Wanzhou WOES Intelligent Optimization Energy Saving System Energy Overview Module GetTargetConfig sql injection","id":"CVE-2025-8705","kev_date_added":null,"published":"2025-08-08"},{"cvss_score":5.3,"headline":"Wanzhou WOES Intelligent Optimization Energy Saving System Energy Overview Module CreateFunctionLog sql injection","id":"CVE-2025-8706","kev_date_added":null,"published":"2025-08-08"},{"cvss_score":5.3,"headline":"Wanzhou WOES Intelligent Optimization Energy Saving System GetPageList sql injection","id":"CVE-2025-8701","kev_date_added":null,"published":"2025-08-07"},{"cvss_score":5.3,"headline":"SQL injection in WOES Intelligent Optimization Energy Saving System","id":"CVE-2025-8702","kev_date_added":null,"published":"2025-08-07"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-08-08","vendors":["Wanzhou"]},"summary":"Remote attackers can exploit SQL injection in the Environmental Real-Time Data Module to read or modify database contents.","url":"https://insights.sbomify.com/CVE-2025-8703/"}