{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-9437 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-9437 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-9437 is a high-severity denial of service vulnerability in Rockwell Automation ArmorStart AOP, published on 14 Oct 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-9437 and fix it if it is affected.\n\nWhat it is: CVE-2025-9437 is a high-severity denial of service vulnerability in Rockwell Automation ArmorStart AOP, published on 14 Oct 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-9437 in the wild and no public exploit code.\n\nAffected product: Rockwell Automation ArmorStart AOP. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-9437/ (Markdown: https://insights.sbomify.com/CVE-2025-9437/index.md)","id":"CVE-2025-9437","markdown":"https://insights.sbomify.com/CVE-2025-9437/index.md","name":"CVE-2025-9437","record":{"aliases":["GHSA-3p4f-g732-2rg3"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial motor controller","requires_auth":"none","summary":"Attackers can cause denial of service in Rockwell ArmorStart motor controllers by inputting invalid values into COM methods within the Studio 5000 Logix Designer add-on profile.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Rockwell","cpe":[],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-755","name":"Improper Handling of Exceptional Conditions"}],"description":"A security issue exists within the Studio 5000 Logix Designer add-on profile (AOP) for the ArmorStart Classic distributed motor controller, resulting in denial-of-service. This vulnerability is possible due to the input of invalid values into Component Object Model (COM) methods.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Rockwell Automation ArmorStart® AOP Denial-of-Service Vulnerability","id":"CVE-2025-9437","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"1000projects Online Project Report Submission and Evaluation System add_student.php cross site scripting","id":"CVE-2025-9438"},"packages":[],"prev":{"headline":"Cross-site scripting in Widgets for Google Reviews","id":"CVE-2025-9436"},"products":["ArmorStart AOP"],"published":"2025-10-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-10-14","vendors":["Rockwell Automation"]},"summary":"Attackers can cause denial of service in Rockwell ArmorStart motor controllers by inputting invalid values into COM methods within the Studio 5000 Logix Designer add-on profile.","url":"https://insights.sbomify.com/CVE-2025-9437/"}