{"answers":{"affected":"It affects 6 products.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-9575 exists.","fix":"No fix has been published for CVE-2025-9575 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-9575 is a medium-severity command injection vulnerability in Linksys Re6250 Firmware, published on 28 Aug 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-9575 and fix it if it is affected.\n\nWhat it is: CVE-2025-9575 is a medium-severity command injection vulnerability in Linksys Re6250 Firmware, published on 28 Aug 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-9575 exists.\n\nAffected product: Linksys Re6250 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-9575/ (Markdown: https://insights.sbomify.com/CVE-2025-9575/index.md)","id":"CVE-2025-9575","markdown":"https://insights.sbomify.com/CVE-2025-9575/index.md","name":"CVE-2025-9575","record":{"aliases":["GHSA-qh3h-2x77-r3c4"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Linksys Wi-Fi Range Extender","requires_auth":"low_privilege","summary":"Remote attackers can execute arbitrary OS commands via the filename argument in upload.cgi on Linksys range extenders.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"re6250_firmware","vendor":"linksys"},{"product":"re6300_firmware","vendor":"linksys"},{"product":"re6350_firmware","vendor":"linksys"},{"product":"re6500_firmware","vendor":"linksys"},{"product":"re7000_firmware","vendor":"linksys"},{"product":"re9000_firmware","vendor":"linksys"}],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"description":"A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function cgiMain of the file /cgi-bin/upload.cgi. Executing manipulation of the argument filename can lead to os command injection. The attack may be performed from a remote location. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 upload.cgi cgiMain os command injection","id":"CVE-2025-9575","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"linksys:re6250_firmware","products":["linksys:re6250_firmware","linksys:re6300_firmware","linksys:re6350_firmware","linksys:re6500_firmware","linksys:re7000_firmware","linksys:re9000_firmware"],"type":"command_injection","year":"2025"},"n_packages":0,"n_references":6,"next":{"headline":"seeedstudio ReSpeaker Administrative shadow default credentials","id":"CVE-2025-9576"},"packages":[],"prev":{"headline":"Missing Authentication Vulnerability","id":"CVE-2025-9574"},"products":["RE6250","RE6300","RE6350","RE6500","RE7000","RE9000"],"published":"2025-08-28","related":[{"cvss_score":8.7,"headline":"Memory corruption in RE6250","id":"CVE-2025-14133","kev_date_added":null,"published":"2025-12-06"},{"cvss_score":8.7,"headline":"Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow","id":"CVE-2025-14134","kev_date_added":null,"published":"2025-12-06"},{"cvss_score":8.7,"headline":"Memory corruption in RE6250","id":"CVE-2025-14135","kev_date_added":null,"published":"2025-12-06"},{"cvss_score":8.7,"headline":"Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow","id":"CVE-2025-14136","kev_date_added":null,"published":"2025-12-06"},{"cvss_score":8.7,"headline":"Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setIpv6 stack-based overflow","id":"CVE-2025-9481","kev_date_added":null,"published":"2025-08-26"},{"cvss_score":8.7,"headline":"Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 portRangeForwardAdd stack-based overflow","id":"CVE-2025-9482","kev_date_added":null,"published":"2025-08-26"},{"cvss_score":8.7,"headline":"Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 singlePortForwardAdd stack-based overflow","id":"CVE-2025-9483","kev_date_added":null,"published":"2025-08-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-08-28","vendors":["Linksys"]},"summary":"Remote attackers can execute arbitrary OS commands via the filename argument in upload.cgi on Linksys range extenders.","url":"https://insights.sbomify.com/CVE-2025-9575/"}