{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-9828 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-9828 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-9828 is a medium-severity vulnerability in Tenda CP6, published on 2 Sep 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-9828 and fix it if it is affected.\n\nWhat it is: CVE-2025-9828 is a medium-severity vulnerability in Tenda CP6, published on 2 Sep 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-9828 in the wild and no public exploit code.\n\nAffected product: Tenda CP6. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-9828/ (Markdown: https://insights.sbomify.com/CVE-2025-9828/index.md)","id":"CVE-2025-9828","markdown":"https://insights.sbomify.com/CVE-2025-9828/index.md","name":"CVE-2025-9828","record":{"aliases":["GHSA-xfx9-5x3p-32f4"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["data_read","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda CP6 camera","requires_auth":"none","summary":"A remote attacker can exploit risky cryptographic algorithms in the uhttp component to potentially bypass security controls or access sensitive data.","user_interaction":"not_required","vuln_class":"weak_cryptography"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"cp6_firmware","vendor":"tenda"}],"cvss":{"score":6.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-327","name":"Use of a Broken or Risky Cryptographic Algorithm"},{"id":"CWE-310","name":null}],"description":"A vulnerability was determined in Tenda CP6 11.10.00.243. The affected element is the function sub_2B7D04 of the component uhttp. Executing manipulation can lead to risky cryptographic algorithm. The attack may be launched remotely. This attack is characterized by high complexity. The exploitability is described as difficult. The exploit has been publicly disclosed and may be utilized.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Tenda CP6 uhttp sub_2B7D04 risky encryption","id":"CVE-2025-9828","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"weak_cryptography","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"PHPGurukul Beauty Parlour Management System signup.php sql injection","id":"CVE-2025-9829"},"packages":[],"prev":{"headline":"Cross-site scripting in Hubshare","id":"CVE-2025-9826"},"products":["CP6"],"published":"2025-09-02","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-09-02","vendors":["Tenda"]},"summary":"A remote attacker can exploit risky cryptographic algorithms in the uhttp component to potentially bypass security controls or access sensitive data.","url":"https://insights.sbomify.com/CVE-2025-9828/"}