{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-101265 exists.","fix":"No fix has been published for CVE-2026-101265 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-101265 is a low-severity vulnerability in Intelbras TIP 125i, published on 28 Sep 2026. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-101265 and fix it if it is affected.\n\nWhat it is: CVE-2026-101265 is a low-severity vulnerability in Intelbras TIP 125i, published on 28 Sep 2026. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-101265 exists.\n\nAffected product: Intelbras TIP 125i. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-101265/ (Markdown: https://insights.sbomify.com/CVE-2026-101265/index.md)","id":"CVE-2026-101265","markdown":"https://insights.sbomify.com/CVE-2026-101265/index.md","name":"CVE-2026-101265","record":{"aliases":["GHSA-c7j5-fj65-gwq4"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Intelbras IP Camera","requires_auth":"low_privilege","summary":"Remote attackers can access sensitive information embedded in the source code of the Intelbras TIP 125i camera's basic page.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[],"cvss":{"score":2.3,"severity":"low","source":"cna","vector":"CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-540","name":"Inclusion of Sensitive Information in Source Code"},{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"A vulnerability was identified in Intelbras TIP 125i 4.3.35/4.3.41. The affected element is an unknown function of the component Básico Page. Such manipulation leads to inclusion of sensitive information in source code. The attack can be launched remotely. A high complexity level is associated with this attack. The exploitability is described as difficult. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Intelbras TIP 125i Básico sensitive information in source","id":"CVE-2026-101265","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2026"},"n_packages":0,"n_references":4,"next":{"headline":"Checkout validation bypass","id":"CVE-2026-101266"},"packages":[],"prev":{"headline":"Ziroom ZHOME A0101 set_passwd command injection","id":"CVE-2026-101264"},"products":["TIP 125i"],"published":"2026-09-28","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-09-29","vendors":["Intelbras"]},"summary":"Remote attackers can access sensitive information embedded in the source code of the Intelbras TIP 125i camera's basic page.","url":"https://insights.sbomify.com/CVE-2026-101265/"}