{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-102298 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-102298 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-102298 is a high-severity missing authorization vulnerability in TP-Link System Inc. Omada Software Controller (Windows), published on 14 Oct 2026. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-102298 and fix it if it is affected.\n\nWhat it is: CVE-2026-102298 is a high-severity missing authorization vulnerability in TP-Link System Inc. Omada Software Controller (Windows), published on 14 Oct 2026. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-102298 in the wild and no public exploit code.\n\nAffected product: TP-Link System Inc. Omada Software Controller (Windows). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-102298/ (Markdown: https://insights.sbomify.com/CVE-2026-102298/index.md)","id":"CVE-2026-102298","markdown":"https://insights.sbomify.com/CVE-2026-102298/index.md","name":"CVE-2026-102298","record":{"aliases":["GHSA-992g-w5j8-qhcq"],"analysis":{"component_type":"server_software","fix_type":"patch","impacts":["data_read","account_takeover"],"network_reachable":"yes","non_default_config":true,"product_category":"Omada Software Controller","requires_auth":"high_privilege","summary":"Authenticated users can bypass authorization checks to enumerate users and verify credentials for other accounts in Omada Controller MSP mode.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"TPLink","cpe":[],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-862","name":"Missing Authorization"},{"id":"CWE-639","name":"Authorization Bypass Through User-Controlled Key"}],"description":"In Omada Controller MSP mode, the user-confirmation endpoint fails to enforce the required permission check. An authenticated user can supply a caller-controlled Identifier parameter to validate credentials for another account and receive responses that distinguish nonexistent users, invalid passwords, and successful authentication. \n\nSuccessful exploitation may allow user enumeration, credential verification, and unauthorized access to MSP resources or compromise of targeted accounts.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Insufficient Authorization and User Boundary Validation in Omada Controller MSP","id":"CVE-2026-102298","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2026"},"n_packages":0,"n_references":3,"next":{"headline":"Memory corruption in Chrome","id":"CVE-2026-102299"},"packages":[],"prev":{"headline":"ZoneMinder before 1.38.4 Incorrect Authorization in frames API index","id":"CVE-2026-102297"},"products":["Omada Software Controller (Windows)"],"published":"2026-10-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-10-16","vendors":["TP-Link System Inc."]},"summary":"Authenticated users can bypass authorization checks to enumerate users and verify credentials for other accounts in Omada Controller MSP mode.","url":"https://insights.sbomify.com/CVE-2026-102298/"}