{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-106171 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-106171 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-106171 is a medium-severity command injection vulnerability in Fortinet FortiManager, published on 13 Oct 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-106171 and fix it if it is affected.\n\nWhat it is: CVE-2026-106171 is a medium-severity command injection vulnerability in Fortinet FortiManager, published on 13 Oct 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-106171 in the wild and no public exploit code.\n\nAffected product: Fortinet FortiManager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-106171/ (Markdown: https://insights.sbomify.com/CVE-2026-106171/index.md)","id":"CVE-2026-106171","markdown":"https://insights.sbomify.com/CVE-2026-106171/index.md","name":"CVE-2026-106171","record":{"aliases":["GHSA-27gm-32wm-96j2"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["privilege_escalation","code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Fortinet FortiManager","requires_auth":"high_privilege","summary":"Attackers can escalate privileges via OS command injection in FortiManager by sending specially crafted packets.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"fortinet","cpe":[],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H/E:U/RL:O/RC:C","version":"3.1"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"A improper neutralization of special elements used in an os command ('os command injection') vulnerability in Fortinet FortiManager 8.0.0, FortiManager 7.6.0 through 7.6.6, FortiManager Cloud 7.6.2 through 7.6.6 may allow attacker to escalation of privilege via specially crafted packets","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in FortiManager","id":"CVE-2026-106171","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Hardcoded credentials in FortiSandbox","id":"CVE-2026-106172"},"packages":[],"prev":{"headline":"Denial of service in FortiSandbox","id":"CVE-2026-106170"},"products":["FortiManager","FortiManager Cloud"],"published":"2026-10-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-10-14","vendors":["Fortinet"]},"summary":"Attackers can escalate privileges via OS command injection in FortiManager by sending specially crafted packets.","url":"https://insights.sbomify.com/CVE-2026-106171/"}