{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-111220 exists.","fix":"No fix has been published for CVE-2026-111220 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-111220 is a high-severity command injection vulnerability in Netgate pfSense CE, published on 15 Oct 2026. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-111220 and fix it if it is affected.\n\nWhat it is: CVE-2026-111220 is a high-severity command injection vulnerability in Netgate pfSense CE, published on 15 Oct 2026. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-111220 exists.\n\nAffected product: Netgate pfSense CE. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-111220/ (Markdown: https://insights.sbomify.com/CVE-2026-111220/index.md)","id":"CVE-2026-111220","markdown":"https://insights.sbomify.com/CVE-2026-111220/index.md","name":"CVE-2026-111220","record":{"aliases":["GHSA-cx43-pf3x-hc6x"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"pfSense CE","requires_auth":"high_privilege","summary":"Authenticated users with PPP edit privileges can inject commands into crontab to execute arbitrary code as root on pfSense CE.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[],"cvss":{"score":8.6,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-93","name":"Improper Neutralization of CRLF Sequences"}],"description":"pfSense CE through 2.9.0 contains a crontab injection vulnerability in interfaces_ppps_edit.php that allows authenticated users to execute commands as root by injecting newlines into the ptpid or reset hour/minute fields. Attackers holding the 'WebCfg - Interfaces: PPPs: Edit' privilege can submit crafted POST values that configure_cron() writes unescaped into /etc/crontab, running arbitrary root commands on schedule.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Netgate pfSense CE through 2.9.0 Crontab Injection via PPP Periodic Reset ptpid","id":"CVE-2026-111220","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2026"},"n_packages":0,"n_references":6,"next":{"headline":"Netgate pfSense CE through 2.9.0 Command Injection via RADIUS Secret mpd.conf Injection","id":"CVE-2026-111221"},"packages":[],"prev":{"headline":"Netgate pfSense CE through 2.9.0 Command Injection via PPPoE Server Username","id":"CVE-2026-111219"},"products":["pfSense CE"],"published":"2026-10-15","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-10-15","vendors":["Netgate"]},"summary":"Authenticated users with PPP edit privileges can inject commands into crontab to execute arbitrary code as root on pfSense CE.","url":"https://insights.sbomify.com/CVE-2026-111220/"}