{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-11493 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-11493 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-11493 is a low-severity vulnerability in Tenda AC15, published on 8 Jun 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-11493 and fix it if it is affected.\n\nWhat it is: CVE-2026-11493 is a low-severity vulnerability in Tenda AC15, published on 8 Jun 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-11493 in the wild and no public exploit code.\n\nAffected product: Tenda AC15. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-11493/ (Markdown: https://insights.sbomify.com/CVE-2026-11493/index.md)","id":"CVE-2026-11493","markdown":"https://insights.sbomify.com/CVE-2026-11493/index.md","name":"CVE-2026-11493","record":{"aliases":["GHSA-r2vf-hwwr-q9jg"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Tenda AC15 router","requires_auth":"none","summary":"Weak password requirements in the Samba configuration of Tenda AC15 routers allow local attackers to bypass authentication controls.","user_interaction":"not_required","vuln_class":"weak_cryptography"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[],"cvss":{"score":2.3,"severity":"low","source":"cna","vector":"CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-521","name":"Weak Password Requirements"}],"description":"A weakness has been identified in Tenda AC15 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/smb.conf of the component Samba. Executing a manipulation can lead to weak password requirements. The attack is only possible within the local network. A high complexity level is associated with this attack. The exploitability is regarded as difficult. The exploit has been made available to the public and could be used for attacks.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Tenda AC15 Samba smb.conf weak password","id":"CVE-2026-11493","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"weak_cryptography","year":"2026"},"n_packages":0,"n_references":6,"next":{"headline":"TOTOLINK AC1200 T8 vsftpd vsftpd.conf least privilege violation","id":"CVE-2026-11494"},"packages":[],"prev":{"headline":"D-Link DIR-823G vsftpd vsftpd.conf least privilege violation","id":"CVE-2026-11492"},"products":["AC15"],"published":"2026-06-08","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-06-08","vendors":["Tenda"]},"summary":"Weak password requirements in the Samba configuration of Tenda AC15 routers allow local attackers to bypass authentication controls.","url":"https://insights.sbomify.com/CVE-2026-11493/"}