{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-1227 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-1227 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-1227 is a high-severity vulnerability in Schneider Electric EcoStruxure Building Operation Webstation, published on 11 Feb 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2026-1227 and fix it if it is affected.\n\nWhat it is: CVE-2026-1227 is a high-severity vulnerability in Schneider Electric EcoStruxure Building Operation Webstation, published on 11 Feb 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2026-1227 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure Building Operation Webstation. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-1227/ (Markdown: https://insights.sbomify.com/CVE-2026-1227/index.md)","id":"CVE-2026-1227","markdown":"https://insights.sbomify.com/CVE-2026-1227/index.md","name":"CVE-2026-1227","record":{"aliases":["GHSA-67mv-4hj2-xp3g"],"analysis":{"component_type":"server_software","fix_type":"patch","impacts":["data_read","denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Building Operation Server","requires_auth":"low_privilege","summary":"A local user can upload a malicious TGML file to the EBO server, causing local file disclosure or denial of service.","user_interaction":"required","vuln_class":"xxe"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-611","name":"Improper Restriction of XML External Entity Reference"}],"description":"CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized disclosure of local files, interaction within the EBO system, or denial of service conditions when a local user uploads a specially crafted TGML graphics file to the EBO server from Workstation.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"XML external entity in EcoStruxure Building Operation Webstation","id":"CVE-2026-1227","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xxe","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in Timeline Block – Beautiful Timeline Builder for WordPress (Vertical \u0026 Horizontal Timelines)","id":"CVE-2026-1228"},"packages":[],"prev":{"headline":"Code injection in EcoStruxure Building Operation Webstation","id":"CVE-2026-1226"},"products":["EcoStruxure Building Operation Webstation","EcoStruxure Building Operation Workstation"],"published":"2026-02-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-02-11","vendors":["Schneider Electric"]},"summary":"A local user can upload a malicious TGML file to the EBO server, causing local file disclosure or denial of service.","url":"https://insights.sbomify.com/CVE-2026-1227/"}