{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2026-129255 in the wild and no public exploit code.","exposure":"Having an affected version installed is enough. The problem is in what it ships or how it installs, so no code has to call it.","fix":"No fix has been published for CVE-2026-129255 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-129255 is a critical insecure configuration vulnerability in CoolerMaster MASTERPLUS+, published on 14 Nov 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-129255 and fix it if it is affected.\n\nWhat it is: CVE-2026-129255 is a critical insecure configuration vulnerability in CoolerMaster MASTERPLUS+, published on 14 Nov 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-129255 in the wild and no public exploit code.\nExposure: Having an affected version installed is enough. The problem is in what it ships or how it installs, so no code has to call it.\n\nAffected product: CoolerMaster MASTERPLUS+. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-129255/ (Markdown: https://insights.sbomify.com/CVE-2026-129255/index.md)","id":"CVE-2026-129255","markdown":"https://insights.sbomify.com/CVE-2026-129255/index.md","name":"CVE-2026-129255","record":{"aliases":["GHSA-hfjg-wrx8-4h72"],"analysis":{"component_type":"desktop_application","exploitable_when_present":true,"fix_type":"no_fix_stated","impacts":["privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"hardware utility driver","requires_auth":"low_privilege","requires_specific_call":false,"summary":"Local attackers can abuse incorrect default permissions in the CoolerMaster MASTERPLUS+ WinRing0x64.sys driver to escalate privileges.","user_interaction":"not_required","vuln_class":"misconfiguration","vulnerable_functions":["sub_11504"]},"analysis_generated_by":"sbomify/insights-2b-fp8","assigner":"VulDB","cpe":[{"criteria":[{"cpe":"cpe:2.3:a:coolermaster:masterplus_:*:*:*:*:*:*:*:*","source":"cna","version_end_including":"1.9.6","version_start_including":"1.9.6"}],"n_criteria":1,"name":null,"product":"masterplus_","vendor":"coolermaster"}],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X","version":"4.0"},"cwes":[{"id":"CWE-276","name":"Incorrect Default Permissions"},{"id":"CWE-266","name":"Incorrect Privilege Assignment"}],"description":"A vulnerability was identified in CoolerMaster MASTERPLUS+ 1.9.6. This affects the function sub_11504 in the library WinRing0x64.sys of the component Device Driver. The manipulation of the argument PhysicalAddress leads to incorrect default permissions. The attack can only be performed from a local environment. The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"CoolerMaster MASTERPLUS+ Device Driver WinRing0x64.sys sub_11504 default permission","id":"CVE-2026-129255","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"misconfiguration","year":"2026"},"n_packages":0,"n_references":4,"n_vendor_status":0,"next":{"headline":"Tenda AC18 Firmware Upgrade upgrade data authenticity","id":"CVE-2026-129258"},"nickname":null,"packages":[],"prev":{"headline":"Opixido OCMS Admin TUI index.php cross site scripting","id":"CVE-2026-129254"},"products":["MASTERPLUS+"],"published":"2026-11-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2026-11-14","vendor_status":[],"vendors":["CoolerMaster"]},"summary":"Local attackers can abuse incorrect default permissions in the CoolerMaster MASTERPLUS+ WinRing0x64.sys driver to escalate privileges.","url":"https://insights.sbomify.com/CVE-2026-129255/"}