{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-13207 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-13207 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-13207 is a high-severity authentication bypass vulnerability in Frangoteam FUXA SCADA/HMI, published on 30 Jun 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-13207 and fix it if it is affected.\n\nWhat it is: CVE-2026-13207 is a high-severity authentication bypass vulnerability in Frangoteam FUXA SCADA/HMI, published on 30 Jun 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-13207 in the wild and no public exploit code.\n\nAffected product: Frangoteam FUXA SCADA/HMI. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-13207/ (Markdown: https://insights.sbomify.com/CVE-2026-13207/index.md)","id":"CVE-2026-13207","markdown":"https://insights.sbomify.com/CVE-2026-13207/index.md","name":"CVE-2026-13207","record":{"aliases":["GHSA-cgxf-x59w-2x25"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA HMI software","requires_auth":"none","summary":"Attackers can bypass authentication in FUXA SCADA/HMI to access sensitive user and role data via path normalization flaws.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-290","name":"Authentication Bypass by Spoofing"}],"description":"FUXA versions 1.3.1 and prior contain an authentication bypass vulnerability via dot-segment path normalization in the REST API. The API router fails to normalize dot-segment sequences before applying authentication middleware, allowing unauthenticated requests to access protected endpoints by prefixing paths with dot-segments such as /api/./users, /api/./roles, and /api/project/../users. These requests bypass authentication checks and return sensitive user and role data without credentials.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":false,"headline":"Frangoteam FUXA SCADA/HMI Authentication Bypass by Spoofing","id":"CVE-2026-13207","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2026"},"n_packages":0,"n_references":3,"next":{"headline":"Auth bypass in Red Hat OpenShift Virtualization 4","id":"CVE-2026-13208"},"packages":[],"prev":{"headline":"Multiple Vulnerabilities in Zyxel's WAH7601 - OS Command Injection","id":"CVE-2026-13206"},"products":["FUXA SCADA/HMI"],"published":"2026-06-30","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-07-01","vendors":["Frangoteam"]},"summary":"Attackers can bypass authentication in FUXA SCADA/HMI to access sensitive user and role data via path normalization flaws.","url":"https://insights.sbomify.com/CVE-2026-13207/"}