{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-13211 exists.","fix":"No fix has been published for CVE-2026-13211 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-13211 is a medium-severity vulnerability in genua genucenter, published on 1 Jul 2026. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-13211 and fix it if it is affected.\n\nWhat it is: CVE-2026-13211 is a medium-severity vulnerability in genua genucenter, published on 1 Jul 2026. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-13211 exists.\n\nAffected product: genua genucenter. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-13211/ (Markdown: https://insights.sbomify.com/CVE-2026-13211/index.md)","id":"CVE-2026-13211","markdown":"https://insights.sbomify.com/CVE-2026-13211/index.md","name":"CVE-2026-13211","record":{"aliases":["GHSA-296j-g5j7-v64q"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"genucenter network appliance","requires_auth":"low_privilege","summary":"The genucenter web interface exposes sensitive SNMP credentials to authenticated users, allowing potential network configuration compromise.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"sba-research","cpe":[],"cvss":{"score":4.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-201","name":"Insertion of Sensitive Information Into Sent Data"}],"description":"The genucenter web interface before version 8.0p11 unnecessarily exposes sensitive SNMP authentication and encryption keys in its HTTP responses to users with the “Service” or “Admin” role.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Genucenter Disclosure of SNMP Credentials","id":"CVE-2026-13211","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Zephyr virtio driver calls an arbitrary function pointer from an out-of-range used-ring descriptor id","id":"CVE-2026-13212"},"packages":[],"prev":{"headline":"Incorrect Authorization in GitLab","id":"CVE-2026-13210"},"products":["genucenter"],"published":"2026-07-01","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-07-01","vendors":["genua"]},"summary":"The genucenter web interface exposes sensitive SNMP credentials to authenticated users, allowing potential network configuration compromise.","url":"https://insights.sbomify.com/CVE-2026-13211/"}