{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2026-133850 in the wild and no public exploit code.","exposure":"","fix":"Upgrade flowintel to 4.1.0 or later. The advisory says that version fixes it.","what":"CVE-2026-133850 is a medium-severity vulnerability in flowintel, published on 20 Nov 2026."},"fix_prompt":"Check this codebase for CVE-2026-133850 and fix it if it is affected.\n\nWhat it is: CVE-2026-133850 is a medium-severity vulnerability in flowintel, published on 20 Nov 2026. \nExploitation: There is no known exploitation of CVE-2026-133850 in the wild and no public exploit code.\n\nAffected product: flowintel. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-133850/ (Markdown: https://insights.sbomify.com/CVE-2026-133850/index.md)","id":"CVE-2026-133850","markdown":"https://insights.sbomify.com/CVE-2026-133850/index.md","name":"CVE-2026-133850","record":{"aliases":["GHSA-qc34-rp79-2x7r"],"analysis":null,"analysis_generated_by":null,"assigner":"CIRCL","component":null,"cpe":[{"criteria":[{"cpe":"cpe:2.3:a:flowintel:flowintel:*:*:*:*:*:*:*:*","source":"cna","version_end_excluding":"4.1.0"}],"n_criteria":1,"name":"Flowintel","product":"flowintel","vendor":"flowintel"}],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-862","name":"Missing Authorization"},{"id":"CWE-285","name":"Improper Authorization"}],"description":"flowintel contains an authorization flaw in its recurring reminder notification subsystem. When a user is subscribed to recurring notifications for a case, the system does not re-verify the recipient's current access rights to that case before generating or displaying the notification.\n\nAs a result, a user who previously had access to a private case and later had that access revoked can still:\n- Receive recurring reminder notifications containing case-related content.\n- View stored reminder notifications in their notification list, including notification counts, even though they no longer have permission to view the underlying case.\n\nThe vulnerability affects both the notification creation path (recurring reminder generation) and the notification display path (listing and counting stored reminders). The issue arises because the authorization check performed at subscription time is not re-applied at delivery or retrieval time.\n\nSecurity impact is limited to information disclosure: an unauthorized user may observe case titles, reminder messages, and associated metadata that they no longer have permission to access. No integrity or availability impact is indicated by the patch.\n\nAffected versions: flowintel prior to 4.1.0.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":true,"headline":"flowintel: Stale Authorization Allows Notification Disclosure After Case Access Revocation","id":"CVE-2026-133850","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":null,"year":"2026"},"main_cpe":null,"main_fixed":[],"main_package":null,"n_packages":0,"n_references":1,"n_vendor_status":0,"next":{"headline":"FlowIntel Alerting: Missing Private Case Authorization Check Allows Connector Owners to Access Revoked Case Data","id":"CVE-2026-133851"},"nickname":null,"packages":[],"prev":{"headline":"flowintel: Insecure Direct Object Reference in Task Calendar Access Control","id":"CVE-2026-133849"},"products":["flowintel"],"published":"2026-11-20","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","text_fixes":["4.1.0"],"updated":"2026-11-20","vendor_status":[],"vendors":["flowintel"]},"summary":null,"url":"https://insights.sbomify.com/CVE-2026-133850/"}