{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-135789 exists.","exposure":"An affected version is exposed as installed. No special setting or call is needed.","fix":"No fix has been published for CVE-2026-135789 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-135789 is a critical command injection vulnerability in D-Link R95, published on 24 Nov 2026. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-135789 and fix it if it is affected.\n\nWhat it is: CVE-2026-135789 is a critical command injection vulnerability in D-Link R95, published on 24 Nov 2026. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-135789 exists.\nExposure: An affected version is exposed as installed. No special setting or call is needed.\n\nAffected product: D-Link R95. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-135789/ (Markdown: https://insights.sbomify.com/CVE-2026-135789/index.md)","id":"CVE-2026-135789","markdown":"https://insights.sbomify.com/CVE-2026-135789/index.md","name":"CVE-2026-135789","record":{"aliases":["GHSA-rp7j-p7qh-8x54"],"analysis":{"component_type":"network_device","exploitable_when_present":false,"fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"home router","requires_auth":"high_privilege","requires_specific_call":false,"summary":"Remote attackers can inject OS commands via DHMAPI SOAP handlers on D-Link R95 routers; owners should care.","user_interaction":"not_required","vuln_class":"command_injection","vulnerable_functions":["SetBluetoothPairDevice"]},"analysis_generated_by":"sbomify/insights-2b-fp8","assigner":"VulDB","component":null,"cpe":[{"criteria":[{"cpe":"cpe:2.3:h:d-link:r95:*:*:*:*:*:*:*:*","source":"cna","version_end_including":"101B06","version_start_including":"101B06"}],"n_criteria":1,"name":null,"product":"r95","vendor":"d-link"}],"cvss":{"score":9.4,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P","version":"4.0"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"description":"A security vulnerability has been detected in D-Link R95 101B06. Affected by this issue is the function GetBluetoothAdapterSettings/GetBluetoothBloodPressure/GetBluetoothDeviceList/GetBluetoothScanDeviceList/SetBluetoothAdapterSettings/SetBluetoothUnpairDevice/SetTriggerBluetoothScan/SetBluetoothPairDevice of the file /bin/ssi of the component DHMAPI SOAP Handler. The manipulation of the argument inner_xml leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"D-Link R95 DHMAPI SOAP ssi SetBluetoothPairDevice os command injection","id":"CVE-2026-135789","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2026"},"main_cpe":null,"main_fixed":[],"main_package":null,"n_packages":0,"n_references":6,"n_vendor_status":0,"next":{"headline":"Panabit Smart Application Gateway ajax_chart_dump os command injection","id":"CVE-2026-135790"},"nickname":null,"packages":[],"prev":{"headline":"D-Link DIR-X1860 anweb os command injection","id":"CVE-2026-135788"},"products":["R95"],"published":"2026-11-24","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","text_fixes":[],"updated":"2026-11-24","vendor_status":[],"vendors":["D-Link"]},"summary":"Remote attackers can inject OS commands via DHMAPI SOAP handlers on D-Link R95 routers; owners should care.","url":"https://insights.sbomify.com/CVE-2026-135789/"}