{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-14950 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-14950 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-14950 is a critical vulnerability in Frauscher Sensortechnik FDS 102, published on 20 Aug 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-14950 and fix it if it is affected.\n\nWhat it is: CVE-2026-14950 is a critical vulnerability in Frauscher Sensortechnik FDS 102, published on 20 Aug 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-14950 in the wild and no public exploit code.\n\nAffected product: Frauscher Sensortechnik FDS 102. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-14950/ (Markdown: https://insights.sbomify.com/CVE-2026-14950/index.md)","id":"CVE-2026-14950","markdown":"https://insights.sbomify.com/CVE-2026-14950/index.md","name":"CVE-2026-14950","record":{"aliases":["GHSA-3j24-9cjq-wm9f"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["account_takeover","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Frauscher FDS 102","requires_auth":"none","summary":"An attacker with a valid session ID can maintain unauthorized access to the FDS web interface after the session should have expired.","user_interaction":"not_required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"CERTVDE","cpe":[],"cvss":{"score":9.2,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-613","name":"DEPRECATED: Insufficient Session Expiration"}],"description":"An unauthenticated remote attacker in possession of a valid session identifier is able to continue using the session after it should have expired. This increases the risk associated with stolen, leaked, shared, or unattended sessions and may enable unauthorized continued access to the FDS web interface.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Security feature bypass in FDS 102","id":"CVE-2026-14950","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site request forgery in FDS 102","id":"CVE-2026-14951"},"packages":[],"prev":{"headline":"Missing authorization in FDS 102","id":"CVE-2026-14949"},"products":["FDS 102"],"published":"2026-08-20","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-08-20","vendors":["Frauscher Sensortechnik"]},"summary":"An attacker with a valid session ID can maintain unauthorized access to the FDS web interface after the session should have expired.","url":"https://insights.sbomify.com/CVE-2026-14950/"}