{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-15953 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-15953 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-15953 is a medium-severity path traversal vulnerability in ABB Protection and control IED manager (PCM600), published on 28 Sep 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2026-15953 and fix it if it is affected.\n\nWhat it is: CVE-2026-15953 is a medium-severity path traversal vulnerability in ABB Protection and control IED manager (PCM600), published on 28 Sep 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2026-15953 in the wild and no public exploit code.\n\nAffected product: ABB Protection and control IED manager (PCM600). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-15953/ (Markdown: https://insights.sbomify.com/CVE-2026-15953/index.md)","id":"CVE-2026-15953","markdown":"https://insights.sbomify.com/CVE-2026-15953/index.md","name":"CVE-2026-15953","record":{"aliases":["GHSA-469j-4qv8-mjfp"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["data_read","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"ABB IED manager","requires_auth":"low_privilege","summary":"An attacker can exploit path traversal during project archive import to read or modify files outside the intended directory in ABB PCM600.","user_interaction":"required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"ABB","cpe":[],"cvss":{"score":5.6,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:A/VC:N/VI:H/VA:N/SC:N/SI:H/SA:N","version":"4.0"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ABB Protection and control IED manager (PCM600).\n\nThis issue affects Protection and control IED manager (PCM600): through 2.14.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path Traversal During Project Archive Import","id":"CVE-2026-15953","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in Db2","id":"CVE-2026-15955"},"packages":[],"prev":{"headline":"Improper Permission Assignment in Scheduler Service","id":"CVE-2026-15952"},"products":["Protection and control IED manager (PCM600)"],"published":"2026-09-28","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-09-28","vendors":["ABB"]},"summary":"An attacker can exploit path traversal during project archive import to read or modify files outside the intended directory in ABB PCM600.","url":"https://insights.sbomify.com/CVE-2026-15953/"}