{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2026-1694 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-1694 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-1694 is a low-severity vulnerability in arcinfo PcVue, published on 26 Feb 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2026-1694 and fix it if it is affected.\n\nWhat it is: CVE-2026-1694 is a low-severity vulnerability in arcinfo PcVue, published on 26 Feb 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2026-1694 in the wild and no public exploit code.\n\nAffected product: arcinfo PcVue. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-1694/ (Markdown: https://insights.sbomify.com/CVE-2026-1694/index.md)","id":"CVE-2026-1694","markdown":"https://insights.sbomify.com/CVE-2026-1694/index.md","name":"CVE-2026-1694","record":{"aliases":["GHSA-6hjh-5rvg-rp2f"],"analysis":{"component_type":"server_software","fix_type":"configuration_change","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA HMI software","requires_auth":"none","summary":"Default IIS and ASP.NET headers expose sensitive server configuration details in PcVue web features, requiring manual removal during deployment.","user_interaction":"required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"arcinfo","cpe":[{"product":"pcvue","vendor":"arcinfo"}],"cvss":{"score":2.3,"severity":"low","source":"cna","vector":"CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N/AU:Y/R:U/RE:M/U:Clear","version":"4.0"},"cwes":[{"id":"CWE-201","name":"Insertion of Sensitive Information Into Sent Data"}],"description":"HTTP headers are added by the default configuration of IIS and ASP.net, and are not removed at the deployment phase of the webservices used by the WebVue, WebScheduler, TouchVue and SnapVue features of PcVue in version 12.0.0 through 16.3.3 included. It unnecessarily exposes sensitive information about the server configuration.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Server configuration details in HTTP headers","id":"CVE-2026-1694","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"XSS vulnerability upon unsuccessful authentication","id":"CVE-2026-1695"},"packages":[],"prev":{"headline":"Use of vulnerable Resource Owner Password Credentials flow","id":"CVE-2026-1693"},"products":["PcVue"],"published":"2026-02-26","related":[{"cvss_score":9.8,"headline":"ARC Informatique PcVue Deserialization of Untrusted Data","id":"CVE-2020-26867","kev_date_added":null,"published":"2020-10-12"},{"cvss_score":8.4,"headline":"Weak encryption mechanism for User directory","id":"CVE-2026-14868","kev_date_added":null,"published":"2026-07-07"},{"cvss_score":7.5,"headline":"ARC Informatique PcVue Access to Critical Private Variable via Public Method","id":"CVE-2020-26868","kev_date_added":null,"published":"2020-10-12"},{"cvss_score":7.5,"headline":"ARC Informatique PcVue Exposure of Sensitive Information to an Unauthorized Actor","id":"CVE-2020-26869","kev_date_added":null,"published":"2020-10-12"},{"cvss_score":6.8,"headline":"Insecure password storage in User directory","id":"CVE-2026-14867","kev_date_added":null,"published":"2026-07-07"},{"cvss_score":5.5,"headline":"Information disclosure in PcVue","id":"CVE-2022-4312","kev_date_added":null,"published":"2022-12-12"},{"cvss_score":5.5,"headline":"ARC Informatique PcVue","id":"CVE-2022-2569","kev_date_added":null,"published":"2022-08-24"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-03-26","vendors":["arcinfo"]},"summary":"Default IIS and ASP.NET headers expose sensitive server configuration details in PcVue web features, requiring manual removal during deployment.","url":"https://insights.sbomify.com/CVE-2026-1694/"}